93
SPC-3010
SPC-3010
Message
<timestamp>, [SPC-3010], <sequence-number>,, WARNING, <system-name>, <slot number
containing Encryption Engine>, <module name>: SEK integrity failure during
initialization.
Probable Cause
Indicates the Crypto Module internal Secret Encryption Key has been corrupted or has not been
initialized.
Recommended
Run the initEE and regEE commands.
Action
Severity
ERROR
SPC-3011
Message
<timestamp>, [SPC-3011], <sequence-number>,, ERROR, <system-name>, <slot number
containing Encryption Engine>, <module name>: Persistent data storage error: <SP
status code>, KEK: <KEK octet 1> <KEK octet 2> <KEK octet 3> <KEK octet 4>.
Probable Cause
Indicates an attempt to store Crypto Module internal data using the Secret Encryption Key failed -
most likely, the EE has been zeroized or tampered with.
Recommended
Run the initEE and regEE commands, then recover or restore the needed primary and secondary
Action
KEKs.
Severity
ERROR
SPC-3012
Message
<timestamp>, [SPC-3012], <sequence-number>,, ERROR, <system-name>, <slot number
containing Encryption Engine>, <module name>: Persistent data retrieval error: <SP
status code>.
Probable Cause
Indicates an attempt to read Crypto Module internal data using the Secret Encryption Key failed -
most likely, the EE has been zeroized or tampered with.
Recommended
Run initEE and regEE commands, then recover or restore the needed primary and secondary KEKs.
Action
Severity
ERROR
SPC-3013
Message
<timestamp>, [SPC-3013], <sequence-number>,, ERROR, <system-name>, <slot number
containing Encryption Engine>, <module name>: SEK generation failure: <SP status
code>.
Probable Cause
Indicates the Crypto Module internal Secret Encryption Key could not be generated.
578