EM-1063
EM-1063
Message
<timestamp>, [EM-1063], <sequence-number>,, CRITICAL, <system-name>, Blade in
slot <Slot Id> faulted because it exceeds the maximum support limit of <Limit>
blades with Blade IDs <Applicable blade Type IDs> in the chassis.
Probable Cause
Indicates too many blades of a set of particular types are in the system.
Recommended
Remove the faulted blade.
Action
Severity
CRITICAL
EM-1064
Message
<timestamp>, [EM-1064], <sequence-number>,, CRITICAL, <system-name>, Blade:<slot
ID> is being powered off (based on user configuration) upon receiving a HW ASIC
ERROR, reason:<Fault reason>.
Probable Cause
Indicates the blade is being powered off because a hardware (HW) application specific integrated
circuit (ASIC) ERROR was detected, and you have selected to power off the problem blade when
such a condition occurred.
Recommended
Contact the switch provider for support.
Action
Severity
CRITICAL
EM-1065
Message
<timestamp>, [EM-1065], <sequence-number>,, WARNING, <system-name>, SSAS
Virtualization Services are not available due to incompatibility between the FOS
and SAS versions<Slot number or blank for single board systems>.
Probable Cause
Indicates the version of either the control processor firmware (CFOS) or the blade processor
firmware (BFOS) is not compatible with the Storage Application Services (SAS) or other application
firmware versions.
Recommended
Upgrade the FOS firmware or the SAS firmware with the firmwareDownload command. Refer to the
Action
release notes for a compatible version of firmware.
Severity
WARNING
EM-1066
Message
<timestamp>, [EM-1066], <sequence-number>,, INFO, <system-name>, SAS
Virtualization Services are now available <Slot number or blank for single board
systems>.