CEE CONFIG System Messages

CCFG-1001
Message
<timestamp>, [CCFG-1001], <sequence-number>,, ERROR, <system-name>, Failed to
initialize <module>, rc = <error>.
Probable Cause
Indicates that initialization of a module within the Converged Enhanced Ethernet (CEE)
configuration management daemon has failed.
Recommended
Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS
Action
Command Reference Manual for more information on this command.
Severity
ERROR
CCFG-1002
Message
<timestamp>, [CCFG-1002], <sequence-number>,, INFO, <system-name>, Started
loading CEE system configuration.
Probable Cause
Indicates that the Converged Enhanced Ethernet (CEE) system configuration has started loading.
Recommended
No action is required.
Action
Severity
INFO
CCFG-1003
Message
<timestamp>, [CCFG-1003], <sequence-number>,, INFO, <system-name>, System is
ready to accept CEE user commands.
Probable Cause
Indicates that the Converged Enhanced Ethernet (CEE) shell is ready to accept configuration
commands from the user.
Recommended
No action is required.
Action
Severity
INFO
CCFG-1004
Message
<timestamp>, [CCFG-1004], <sequence-number>,, ERROR, <system-name>, Configuration
replay failed due to missing system startup configuration.