3
AN-1004
AN-1004
Message
<timestamp>, [AN-1004], <sequence-number>,, WARNING, <system-name>, Slot <slot
number>, port <port number within slot number> is a congestion bottleneck.
<percentage of seconds affected by congestion bottlenecking> percent of last
<observation period over which the percentage of affected seconds is reported>
seconds were affected by this condition.
Probable Cause
Indicates that the volume of outgoing traffic at this port is too high for the capacity of the link.
Recommended
Add more capacity on the path, using trunk links if possible.
Action
Severity
WARNING
AN-1005
Message
<timestamp>, [AN-1005], <sequence-number>,, WARNING, <system-name>, Slot <slot
number>, port <port number within slot number> has <bottleneck type> bottleneck
cleared.
Probable Cause
Indicates that the bottleneck was cleared on the port.
Recommended
No action is required.
Action
Severity
WARNING
AN-1010
Message
<timestamp>, [AN-1010], <sequence-number>,, WARNING, <system-name>, Severe
latency bottleneck detected at Slot <slot number> port <port number within slot
number>.
Probable Cause
Indicates a credit loss.
Recommended
Contact your vendor's customer support for assistance.