Brocade Communications Systems 8 Reference page 259

Fabric os message reference
Hide thumbs Also See for 8:
Table of Contents

Advertisement

Recommended
No action is required.
Action
Severity
INFO
FABR-1030
Message
<timestamp>, [FABR-1030], <sequence-number>,, INFO, <system-name>, fabric: Domain
<new domain ID> (was <old domain ID>).
Probable Cause
Indicates that the domain ID has changed.
Recommended
No action is required.
Action
Severity
INFO
FABR-1031
Message
<timestamp>, [FABR-1031], <sequence-number>, FFDC, WARNING, <system-name>,
Maximum number of retries sending ILS from port
Probable Cause
Indicates the fabric exhausted the maximum number of retries sending internal link service (ILS) to
the iswitchd demon on the specified E_Port.
Recommended
Run the top command to see if iswitchd is extremely busy or if another process is using excessive
Action
CPU resources.
Severity
WARNING
FABR-1032
Message
<timestamp>, [FABR-1032], <sequence-number>, WARNING, <system-name>, Remote
switch with domain ID <domain ID>and switchname <switchname>running an unsupported
FOS version v2.x has joined the fabric.
Probable Cause
Indicates that a switch with an unsupported Fabric OS version 2.x has joined the fabric.
Recommended
Remove the switch with the unsupported Fabric OS version 2.x from the fabric.
Action
Fabric OS Message Reference
53-1001767-01
VC_RDY mode: Virtual-channel flow control mode. This is a proprietary protocol.
R_RDY mode: Receiver-ready flow control mode. This is the Fibre Channel standard protocol,
that uses R_RDY primitive for flow control.
DUAL_CR mode: Dual-credit flow control mode. In both of the previous modes, the buffer
credits are fixed, based on the port configuration information. In this mode, the buffer credits
are negotiated as part of exchange link parameter (ELP) exchange. This mode also uses the
R_RDY primitive for flow control.
FABR-1030
<port number>
exceeded.
26