Brocade Communications Systems 8 Reference page 147

Fabric os message reference
Hide thumbs Also See for 8:
Table of Contents

Advertisement

BL-1037
Message
<timestamp>, [BL-1037], <sequence-number>,, CRITICAL, <system-name>, Faulting
chip in slot = <slot number>, miniS = <miniS number>, port = <port number> due to
BE/BI port fault.
Probable Cause
Indicates a fault on the chip and that all ports on the chip have been disabled.
Recommended
No action is required.
Action
Severity
CRITICAL
BL-1038
Message
<timestamp>, [BL-1038], <sequence-number>,, CRITICAL, <system-name>, Inconsistent
FPGA image version detected, please restart the switch for recovery.
Probable Cause
Indicates that the FPGA image version is incompatible with the software version.
Recommended
Restart the switch. If the message persists, replace the switch.
Action
Severity
CRITICAL
BL-1039
Message
<timestamp>, [BL-1039], <sequence-number>,, CRITICAL, <system-name>, Inconsistent
FPGA image version detected, faulting the blade in slot <slot number>.
Probable Cause
Indicates that the FPGA image version is incompatible with the software version.
Recommended
Power cycle the blade. If the message persists, replace the blade.
Action
Severity
CRITICAL
BL-1041
Message
<timestamp>, [BL-1041], <sequence-number>,, CRITICAL, <system-name>, Dynamic area
mode is enabled on default switch, Faulting the blade w/ ID <Blade ID of blade
that has the mini SFP+ that does not support it> in slot <slot number> as it does
not support this mode.
Probable Cause
Indicates that the blade does not support dynamic area mode on default switch.
Recommended
Turn off the dynamic area mode through Configure CLI.
Action
Severity
CRITICAL
Fabric OS Message Reference
53-1001767-01
7
BL-1037
71

Advertisement

Table of Contents
loading

Table of Contents