PS System Messages

PS-1000
Message
<timestamp>, [PS-1000], <sequence-number>, FFDC, CRITICAL, <system-name>, Failed
to initialize Advanced Performance Monitoring.
Probable Cause
Indicates an unexpected software error has occurred in Advanced Performance Monitoring (APM).
The performance monitor has failed to initialize.
Recommended
The control processor (CP) should restart (or fail over) automatically If this does not happen, restart
Action
or power cycle the switch to re-initiate the firmware.
Severity
CRITICAL
PS-1001
Message
<timestamp>, [PS-1001], <sequence-number>,, INFO, <system-name>, Advanced
Performance Monitoring configuration updated due to change in PID format
Probable Cause
Indicates the PID format was changed.
Recommended
No action is required. Refer to the Fabric OS Administrator's Guide for more information on the PID
Action
format.
Severity
INFO
PS-1002
Message
<timestamp>, [PS-1002], <sequence-number>,, INFO, <system-name>, Failed to
initialize the tracing system for Advanced Performance Monitoring.
Probable Cause
Indicates an unexpected software error has occurred in Advanced Performance Monitoring (APM).
The performance monitor tracing system has failed to initialize.
Recommended
Tracing will not be available for Advanced Performance Monitoring (APM), but other functions will
Action
be normal. To activate tracing, restart (or fail over) the control processor (CP).
Severity
INFO
PS-1003
Message
<timestamp>, [PS-1003], <sequence-number>,, WARNING, <system-name>, Failed to set
end-to-end monitoring mask on ISL ports.