EM-1041
Message
<timestamp>, [EM-1041], <sequence-number>,, WARNING, <system-name>, Sensor values
for <FRU Id>: <Sensor Value> <Sensor Value> <Sensor Value> <Sensor Value> <Sensor
Value> <Sensor Value> <Sensor Value>.
Probable Cause
Indicates that sensors detected a warning condition. All significant sensors for the field-replaceable
unit (FRU) are displayed; each contains a header.
This message can display:
Recommended
If the message is isolated, monitor the error messages on the switch. If the message is associated
Action
with other messages, follow the recommended action for those messages.
Severity
WARNING
EM-1042
Message
<timestamp>, [EM-1042], <sequence-number>,, WARNING, <system-name>, Important FRU
header data for
Probable Cause
Indicates that the specified field-replaceable unit (FRU) has an incorrect number of sensors in its
FRU header-derived information. This could mean that the FRU header was corrupted or read
incorrectly or corrupted in the object database, which contains information about all FRUs.
Recommended
Try reseating the FRU. If the message persists, replace the FRU.
Action
Severity
WARNING
EM-1043
Message
<timestamp>, [EM-1043], <sequence-number>,, WARNING, <system-name>, Can't power
<FRU Id> <state (on or off)>.
Probable Cause
Indicates that the specified field-replaceable unit (FRU) cannot be powered on or off.
Recommended
The specified FRU is not responding to commands and should be replaced.
Action
Severity
WARNING
EM-1044
Message
<timestamp>, [EM-1044], <sequence-number>,, WARNING, <system-name>, Can't power
<FRU Id>
on
Fabric OS Message Reference
53-1001767-01
voltages in volts
temperature in Celsius
fan speeds in RPM
<FRU Id>
, its logical switch is shut down
is not valid).