57
KAC-1008
Probable Cause
Indicates that the key archival client is unable to put to the primary or backup key vault.
Recommended
Determine whether the configured key value is operational, and if it is not, change the switch key
Action
vault settings or resolve the operational problem at the vault.
Severity
ERROR
KAC-1008
Message
<timestamp>, [KAC-1008], <sequence-number>,, ERROR, <system-name>, Putting TEP
failed check if there is already an unapproved TEP then delete it, RC=<Error code
from lkm>.
Probable Cause
Indicates that there was already a pending unapproved TEP at the LKM.
Recommended
Log in to the LKM and delete the unapproved TEP.
Action
Severity
ERROR
KAC-1009
Message
<timestamp>, [KAC-1009], <sequence-number>,, ERROR, <system-name>,
Primary(<Primary Keyvault IP Address>) and secondary(<Secondary Keyvault IP
Address>) keyvaults are not in sync. Detected key mismatch with KeyID = <KeyID>.
Probable Cause
Indicates that primary and secondary contents are not synchronized.
Recommended
Synchronize the contents of the primary and secondary using instructions provided by the provider.
Action
Severity
ERROR
412