19
CVLC-1026
Severity
ERROR
CVLC-1026
Message
<timestamp>, [CVLC-1026], <sequence-number>,, INFO, <system-name>, Some secondary
metadata missing for encrypted LUN configured with -newLUN option.\nContainer:
<Target container name>, Initiator: <Initiator physical WWN>, LUN ID: <LUN ID>.
Probable Cause
Indicates that the secondary metadata does not exist on all LBAs for a LUN that is configured with
--newLUN option.
Recommended
No action is required.
Action
Severity
INFO
CVLC-1027
Message
<timestamp>, [CVLC-1027], <sequence-number>,, ERROR, <system-name>, Encrypted LUN
configured with -newLUN option does not contain any metadata.\nContainer: <Target
container name>, Initiator: <Initiator physical WWN>, LUN ID: <LUN ID>.
Probable Cause
Indicates the metadata was corrupted.
Recommended
No action is required.
Action
Severity
ERROR
CVLC-1028
Message
<timestamp>, [CVLC-1028], <sequence-number>,, WARNING, <system-name>, Not
starting auto rekey on LUN with uncompressible blocks 1-16.\nContainer: <Target
container name>, Initiator: <Initiator physical WWN>, LUN ID: <LUN ID>.
Probable Cause
Indicates a warning event.
Recommended
Perform a manual rekey on this LUN.
Action
Severity
WARNING
CVLC-1029
Message
<timestamp>, [CVLC-1029], <sequence-number>,, WARNING, <system-name>, Mirror LUN
is disabled as primary LUN is being rekeyed without splitting the
mirror.\nContainer: <Target container name>, Initiator: <Initiator physical WWN>,
LUN ID: <LUN ID>.
Probable Cause
Indicates performing FTE or manual rekey of primary LUN without splitting the mirror.
130