Brocade Communications Systems 8 Reference page 123

Fabric os message reference
Hide thumbs Also See for 8:
Table of Contents

Advertisement

Recommended
Usually this problem is transient. The authentication might fail.
Action
Reinitialize authentication using the portDisable and portEnable commands or the switchDisable
and switchEnable commands.
If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers; then run the supportSave command and contact your switch service provider.
Severity
ERROR
AUTH-1031
Message
<timestamp>, [AUTH-1031], <sequence-number>,, ERROR, <system-name>, Failed to
retrieve secret value: port
Probable Cause
Indicates that the secret value was not set properly for the authenticated entity.
Recommended
Reset the secret value by using the secAuthSecret command.
Action
Reinitialize authentication using the portDisable and portEnable commands or the switchDisable
and switchEnable commands.
Severity
ERROR
AUTH-1032
Message
<timestamp>, [AUTH-1032], <sequence-number>,, ERROR, <system-name>, Failed to
generate <data type> for <message payload> payload: length <data length>, error
code <error code>, port <port number>.
Probable Cause
Indicates that the authentication process failed to generate specific data (that is, challenge, nonce,
or response data) for an authentication payload. This usually relates to internal failure.
A nonce is a single-use, usually random value used in authentication protocols to prevent replay
attacks.
Recommended
Usually this problem is transient. The authentication might fail.
Action
Reinitialize authentication using the portDisable and portEnable commands or the switchDisable
and switchEnable commands.
If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers; then run the supportSave command and contact your switch service provider.
Severity
ERROR
AUTH-1033
Message
<timestamp>, [AUTH-1033], <sequence-number>,, ERROR, <system-name>, Disable port
<port number> due to unauthorized switch <switch WWN value>.
Probable Cause
Indicates that an entity was not configured in the switch connection control (SCC) policy and tried
to connect to the port.
Fabric OS Message Reference
53-1001767-01
<port number>.
4
AUTH-1031
47

Advertisement

Table of Contents
loading

Table of Contents