98
SWCH-1019
SWCH-1019
Message
<timestamp>, [SWCH-1019], <sequence-number>,, INFO, <system-name>, Device <wwn
name of device> tries to flogi, reject FLOGI as persistent PID is set on device
and port <port number> has user area <area> bound to it.
Probable Cause
Indicates a WWN-PID and PortAddress binding collision.
Recommended
The Peristent PID is set on the device and requested area cannot be assigned because it is user
Action
bound to a different port. Remove the WWN-PID binding or remove portAddress binding and
re-enable the port and then run the wwnaddress --unbind wwn command or the portaddress
--unbind slot/port command.
Severity
INFO
SWCH-1020
Message
<timestamp>, [SWCH-1020], <sequence-number>,, WARNING, <system-name>,HA state out
of sync: Standby CP (ver = <standby SWC version>) does not support QOS links to
AG(Active CP version = <active SWC version>).
Probable Cause
Indicates the standby control processor (CP) does not support links to AG running QOS.
Recommended
Load a firmware version on the standby CP that supports QOS links to AG, using the
Action
firmwareDownload command.
Severity
WARNING
SWCH-1021
Message
<timestamp>, [SWCH-1021], <sequence-number>,, WARNING, <system-name>, HA state
out of sync: Standby CP (ver = <standby SWC version>) does not support Dynamic
area on default switch (Active CP version = <active SWC version>).
Probable Cause
Indicates the standby control processor (CP) does not support dynamic area on default switch.
Recommended
Load a firmware version on the standby CP that supports dynamic area on default switch, using the
Action
firmwareDownload command.
Severity
WARNING
628
Fabric OS Message Reference
53-1001767-01

Advertisement

Table of Contents
loading