HIL-1107
Message
<timestamp>, [HIL-1107], <sequence-number>, FFDC, ERROR, <system-name>, Switch
faulted, <nominal voltage> (<measured voltage>)above threshold.
Probable Cause
Indicates that the switch voltage is above threshold. This message is specific to nonbladed
switches and is not applicable to the Brocade 24000 or 48000.
Recommended
For the Brocade 200E, 3250, 3850, 4012, 4016, 4018, 4020, and 4024, the entire switch must
Action
be replaced because these switches do not have field-replaceable units (FRUs).
For the Brocade 3900, replace the motherboard FRU.
For the Brocade 4100, 4900, 7500, and AP7600, if the 12 volt level is faulty, replace one or both
power supplies; if any other voltage is faulty, replace the entire switch.
Severity
ERROR
HIL-1108
Message
<timestamp>, [HIL-1108], <sequence-number>, FFDC, CRITICAL, <system-name>, Switch
faulted, <nominal voltage> (<measured voltage>) below threshold. System preparing
for reset.
Probable Cause
Indicates that the switch voltage is below threshold. This message is specific to nonbladed
switches and is not applicable to the Brocade 24000 or 48000.
Recommended
For the Brocade 200E, 3250, 3850, 4012, 4016, 4018, 4020, and 4024, the entire switch must
Action
be replaced because these switches do not have field-replaceable units (FRUs).
For the Brocade 3900, replace the motherboard FRU.
For the Brocade 4100, 4900, 7500, and AP7600, if the 12 volt level is faulty, replace one or both
power supplies; if any other voltage is faulty, replace the entire switch.
Severity
CRITICAL
HIL-1201
Message
<timestamp>, [HIL-1201], <sequence-number>,, WARNING< <system-name>, Blower
<blower number>, speed (<measured speed> RPM) above threshold.
Probable Cause
Indicates that the fan speed (in RPMs) has risen above the maximum threshold. A high speed does
not necessarily mean that the fan is faulty.
Recommended
Run the tempShow command to verify that the switch temperatures are within operational ranges.
Action
Refer to the hardware reference manual for the temperature range of your switch.
Make sure that the area is well-ventilated and that the room temperature is within operational
range of your switch. Refer to the hardware reference manual for your switch for the operational
temperature range.
Run the fanShow command to monitor the speed of the fan generating this error.
Fabric OS Message Reference
53-1001767-01
45