No action is required.
Action
Severity
INFO
SWCH-1015
Message
<timestamp>, [SWCH-1015], <sequence-number>,, WARNING, <system-name>, <Function
name> <Description of problem>.
Probable Cause
Indicates that an internal problem has been detected by the software. This is usually an internal
Fabric OS problem or due to file corruption.
Recommended
Restart or power cycle the switch
Action
If the message persists, run the firmwareDownload command to update the firmware.
Severity
WARNING
SWCH-1016
Message
<timestamp>, [SWCH-1016], <sequence-number>,, INFO, <system-name>, Device <wwn
name of device>fdiscs to port <port number>. Static persistent PID set and area
requested not assigned to the device. Reject FDISC.
Probable Cause
Indicates static persistent PID is set and the area requested is not assigned to the device.
Recommended
This is a NPIV device and static peristent PID is set on it, we are not able to assign the area
Action
requested. Remove the static binding to have the device come up with a different area and run the
wwnaddress --unbind wwn command.
Severity
INFO
SWCH-1017
Message
<timestamp>, [SWCH-1017], <sequence-number>,, INFO, <system-name>, Device <wwn
name of device> tries to flogi to port <port number>, reject FLOGI as persistent
PID is set on the Loop device.
Probable Cause
Indicates persistent PID is set and static Persistent PID is not supported on the Loop device.
Recommended
This is a LOOP device and peristent PID is set on it. This is not a supported configuration. Remove
Action
the WWN-PID binding and re-enable the port and then run the wwnaddress --unbind wwn
command.
Severity
INFO