Brocade Communications Systems 8 Reference page 283

Fabric os message reference
Hide thumbs Also See for 8:
Table of Contents

Advertisement

Recommended
It is due to a CNA/target driver issue. No action is required.
Action
Severity
WARNING
FCOE-1026
Message
<timestamp>, [FCOE-1026], <sequence-number>,, WARNING, <system-name>, FDISC/FLOGI
mismatch. FDISC addressed to different FCF than base FLOGI.
Probable Cause
Indicates the base port has sent an FLOGI but the subsequent FDISC's that was received on the
switch does not match the original FLOGI.
Recommended
It is due to a CNA/target driver issue. No action is required.
Action
Severity
WARNING
FCOE-1027
Message
<timestamp>, [FCOE-1027], <sequence-number>,, ERROR, <system-name>, <msg>: <mac1>
<mac2> <mac3> <mac4> <mac5> <mac6>.
Probable Cause
Indicates this message is printed if an FDISC is received after an FLOGI but the associated
controller cannot be found.
Recommended
No action is required.
Action
Severity
ERROR
FCOE-1028
Message
<timestamp>, [FCOE-1028], <sequence-number>,, ERROR, <system-name>, <msg>: <wwn1>
<wwn2> <wwn3> <wwn4> <wwn5> <wwn6> <wwn7> <wwn8>.
Probable Cause
Indicates the FCoE device with following WWN is not a member of the login group : WWN will be
printed.
Recommended
Change the FCoE login group policy on the switch for the device to login.
Action
Severity
ERROR
FCOE-1029
Message
<timestamp>, [FCOE-1029], <sequence-number>,, WARNING, <system-name>, Version
mismatch between FIP FDISC and root VN port.
Fabric OS Message Reference
53-1001767-01
31
FCOE-1026
207

Advertisement

Table of Contents
loading

Table of Contents