Brocade Communications Systems 8 Reference page 650

Fabric os message reference
Hide thumbs Also See for 8:
Table of Contents

Advertisement

93
SPC-2009
SPC-2009
Message
<timestamp>, [SPC-2009], <sequence-number>,, CRITICAL, <system-name>, <slot
number containing Encryption Engine>, <module name>: Tamper event:
zeroization.
Probable Cause
Indicates the Tamper event triggered due to a user zeroize request.
Recommended
EE is zeroized. Run the initEE and regEE commands.
Action
Severity
CRITICAL
SPC-2010
Message
<timestamp>, [SPC-2010], <sequence-number>,, CRITICAL, <system-name>, <slot
number containing Encryption Engine>, <module name>: Crypto subsystem cover is
open.
Probable Cause
Indicates the Crypto subsystem cover is open.
Recommended
Close the crypto subsystem cover properly.
Action
Severity
CRITICAL
SPC-2011
Message
<timestamp>, [SPC-2011], <sequence-number>,, INFO, <system-name>, <slot number
containing Encryption Engine>, <module name>: OB1 crypto BIST success.
Probable Cause
Indicates the FPGA BIST was successful.
Recommended
No action is required.
Action
Severity
INFO
SPC-2012
Message
<timestamp>, [SPC-2012], <sequence-number>,, INFO, <system-name>, <slot number
containing Encryption Engine>, <module name>: User zeroization command completed
successfully. Tamper INT status %x.
Probable Cause
Indicates the User zeroization command has completed successfully.
Recommended
EE is zeroized. Run the initEE and regEE commands.
Action
Severity
INFO
574
User
Fabric OS Message Reference
53-1001767-01

Advertisement

Table of Contents
loading

Table of Contents