Brocade Communications Systems 8 Reference page 106

Fabric os message reference
Hide thumbs Also See for 8:
Table of Contents

Advertisement

2
AG-1019
Recommended
Run the switchShow command to display the status of all ports in the system. Run the portCfgShow
Action
command to display a list of ports currently configured as N_Ports. Ensure that the host is
connected to an F_port.
Severity
ERROR
AG-1019
Message
<timestamp>, [AG-1019], <sequence-number>,, WARNING, <system-name>, Unable to
failover N_Port <port>. No other N Port in port group:<pgid> is online.
Probable Cause
Indicates that failover across port groups is not supported.
Recommended
Check whether or not an alternate N_Port is configured in this port group.
Action
Severity
WARNING
AG-1020
Message
<timestamp>, [AG-1020], <sequence-number>,, INFO, <system-name>, F_Ports to
N_Ports route/mapping has been changed.
Probable Cause
Indicates that F_Port -to-N_Port mapping has been changed because the switch has come online
or some new N_Port/F_Port has come online.
Recommended
Run the ag --mapshow command to display the updated F_Port-to-N_Port mapping.
Action
Severity
INFO
AG-1021
Message
<timestamp>, [AG-1021], <sequence-number>,, WARNING, <system-name>, Unable to do
Preferred-Failover of F_Port <port>. Failover across different fabric is not
supported.
Probable Cause
Indicates that the failover does not get blocked between two fabrics, although it is not a supported
configuration.
Recommended
Change the preferred N_Port settings for this F_Port using the ag --prefset command.
Action
Choose the preferred N_Port such that it is in the same fabric as the primary N_Port of this F_Port.
Use the ag --show command to check the fabric connectivity of N_Ports.
Severity
WARNING
30
Fabric OS Message Reference
53-1001767-01

Advertisement

Table of Contents
loading