54
IPS-1005
Probable Cause
Indicates that configured Port Mode is different from the intended use.
Recommended
Change the port configuration (by deleting configured FCIP tunnels or iSCSI sessions) to return the
Action
port mode to neutral before attempting to configure the port for a different mode or use.
Severity
WARNING
IPS-1005
Message
<timestamp>, [IPS-1005], <sequence-number>,, WARNING, <system-name>, Tunnel
Authorization Failure for slot (<slot>) port(ge<port>) tunnel ID(<tunnel number>)
reason (<reason>)
Probable Cause
Indicates that tunnel setup failed because of an authorization failure from the remote side. A
reason for such a failure could be a WWN mismatch.
Recommended
Change the tunnel configuration on one side of the tunnel to authorize the remote side to set up
Action
the tunnel.
Severity
WARNING
IPS-1006
Message
<timestamp>, [IPS-1006], <sequence-number>,, WARNING, <system-name>, Tunnel
Configuration Mismatch for slot (<slot>) port(<port>) tunnel ID(<tunnel number>)
reason (<reason>)
Probable Cause
Indicates that tunnel setup failed because of a configuration mismatch between the two ends. The
reason for such a mismatch could be a Compression setting or WanTOV enforcement.
Recommended
Change the tunnel configuration on one side of the tunnel to match that of the other side to set up
Action
the tunnel.
Severity
WARNING