HAMK System Messages

HAMK-1001
Message
<timestamp>, [HAMK-1001], <sequence-number>, SLOT cp-slot-number | CHASSIS, FFDC,
CRITICAL, <system-name>, Warm recovery failed.
Probable Cause
Indicates the switch failed during the warm recovery.
Recommended
This message triggers a switch reboot automatically and attempts a cold recovery. Run the
Action
supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave
command and contact your switch service provider.
Severity
CRITICAL
HAMK-1002
Message
<timestamp>, [HAMK-1002], <sequence-number>, SLOT cp-slot-number | CHASSIS, INFO,
<system-name>, Heartbeat down.
Probable Cause
Indicates that the active control processor (CP) blade determined that the standby CP blade is
down. This can be a result of an operator-initiated action such as the firmwareDownload command,
the standby CP blade being reset or removed, of an error in the standby CP blade.
Recommended
Monitor the standby CP blade for a few minutes. If this message is due to a standby CP reboot, the
Action
message HAMK-1003 will display after the standby CP has completed the reboot successfully.
If the standby CP does not successfully connect to the active CP after 10 minutes, reboot the
standby CP blade by ejecting the blade and reseating it.
Severity
INFO
HAMK-1003
Message
<timestamp>, [HAMK-1003], <sequence-number>, SLOT cp-slot-number | CHASSIS, INFO,
<system-name>, Heartbeat up.
Probable Cause
Indicates that the active control processor (CP) blade detects the standby CP blade. This message
indicates that the standby CP blade is available to take over in case a failure happens on the active
CP blade.
Recommended
No action is required. This message means that the standby CP is healthy.
Action
Severity
INFO