Brocade Communications Systems 8 Reference page 714

Fabric os message reference
Hide thumbs Also See for 8:
Table of Contents

Advertisement

102
TRCE-1011
Probable Cause
Indicates that the trace daemon (traced), used for transferring trace files, failed to start. The trace
capability within the switch is unaffected. The traced facility is normally restarted automatically by
the system after a brief delay.
Recommended
If the message persists, restart the CP (dual-CP system) or restart the switch.
Action
Run the supportFtp command to set up automatic FTP transfers; then run the supportSave
command and contact your switch service provider.
Severity
ERROR
TRCE-1011
Message
<timestamp>, [TRCE-1011], <sequence-number>,, INFO, <system-name>, Trace dump
manually transferred to target ' <optional string to indicate which slot the dump
is ftped out.> ': <result>.
Probable Cause
Indicates that a manual transfer of trace dump files has occurred.
Recommended
No action is required.
Action
Severity
INFO
TRCE-1012
Message
<timestamp>, [TRCE-1012], <sequence-number>,, WARNING, <system-name>, The system
was unable to retrieve trace information from slot
the attempt was made on>
Probable Cause
Indicates that communication between the main system and the indicated slot is unavailable.
Recommended
Make sure the blade is enabled and retry the command. If the blade is already enabled, run the
Action
supportSave command and contact your switch service provider.
Severity
WARNING
638
.
<Slot number of the blade
Fabric OS Message Reference
53-1001767-01