MS System Messages

MS-1001
Message
<timestamp>, [MS-1001], <sequence-number>,, WARNING, <system-name>, MS Platform
Segmented port=<port number> (<port number (hex)>) (<reason for segmentation>
<domain> (<domain (hex)>))
Probable Cause
Indicates the management server (MS) has segmented from another switch domain at the
specified port number because of errors or inconsistencies defined in the MS platform service.
Recommended
Restart or power cycle the switch.
Action
Severity
WARNING
MS-1002
Message
<timestamp>, [MS-1002], <sequence-number>,, INFO, <system-name>, MS Platform
Service Unstable(<message string><domain number>)
Probable Cause
Indicates the management server (MS) platform service is unstable.
The message string can be one of the following:
The domain number is the target domain that caused the error.
Recommended
The recommended actions are as follows:
Action
Fabric OS Message Reference
53-1001767-01
<No Resp for GCAP from>
The switch did not respond to a request for a GCAP (MS Get Capabilities) command.
<GCAP sup but not PL by>
The GCAP (MS Get Capabilities) is supported but the flag for MS platform service is not set.
<GCAP Rejected (reason =BUSY) by>
The GCAP (MS Get Capabilities) is not supported by another switch.
<Reject EXGPLDB from>
The request to the exchange platform database was rejected. The remote switch might be
busy.
<No Resp for GCAP from>
No action is required.
<GCAP sup but not PL by>
Set the flag for the MS Platform Service.