Save Captured Data Traffic To A File - Digi Connect IT 4 User Manual

Hide thumbs Also See for Connect IT 4:
Table of Contents

Advertisement

Diagnostics
ToS
Total Length
ID
Flags
Fragment Offset
TTL
Protocol
Checksum
Source IP Address
Dest. IP Address
TCP Header
Source Port
Destination Port
Sequence Number
Ack Number
Data Offset
Flags
Window
Checksum
Urgent Pointer
TCP Data
00 00 00 00 00 00
>
where capture_filter is the name of a packet capture configuration. See
capture for the network analyzer
To determine available packet capture configurations, use the ?:
> show anaylzer name ?
name: Name of the capture filter to use.
Format:
test_capture
capture_ping
> show anaylzer name

Save captured data traffic to a file

Data traffic is captured to RAM and when the device reboots, the data is lost. To retain the captured
data, first save the data to a file and then upload the file to a PC.
To save captured traffic data to a file, use the
  Command line
1. Select the device in Remote Manager and click Actions > Open Console, or log into the
Connect IT 4 local command line as a user with full Admin access rights.
Depending on your device configuration, you may be presented with an Access selection
menu. Type admin to access the Admin CLI.
Digi Connect IT® 4 User Guide
: 0x00
: 40 bytes
: 15670 (0x3d36)
: Do not fragment
: 0 (0x0000)
: 128 (0x80)
: TCP (6)
: 0x14bc
: 10.10.74.130
: 10.10.74.72
: 52654
: 22
: 2756443999
: 3995064355
: 5
: ACK
: 2050
: 0xc740
: 0
for more information.
analyzer save
command:
Analyze network traffic
......
Configure packet
880

Advertisement

Table of Contents
loading