Digi Connect IT® 4 User Guide
Set the time to wait before the next test is run. If set to the default value of 0s,
l
the test interval is used.
(config network interface my_wan surelink actions 0)> override_
interval int
(config network interface my_wan surelink actions 0)>
reset_modem: This recovery action is available for WWAN interfaces only.
If reset_modem is selected, complete the following:
Set the number of attempts for this recovery action to perform, before moving
l
to the next recovery action:
(config network interface my_wan surelink actions 0)> max_
attempts int
(config network interface my_wan surelink actions 0)>
The default is 3.
Set the time to wait before the next test is run. If set to the default value of 0s,
l
the test interval is used.
(config network interface my_wan surelink actions 0)> override_
interval int
(config network interface my_wan surelink actions 0)>
switch_sim: Switches to an alternate SIM. This recovery action is available for
WWAN interfaces only.
If switch_sim is selected, complete the following:
Set the number of attempts for this recovery action to perform, before moving
l
to the next recovery action:
(config network interface my_wan surelink actions 0)> max_
attempts int
(config network interface my_wan surelink actions 0)>
The default is 3.
Set the time to wait before the next test is run. If set to the default value of 0s,
l
the test interval is used.
(config network interface my_wan surelink actions 0)> override_
interval int
(config network interface my_wan surelink actions 0)>
modem_power_cycle: This recovery action is available for WWAN interfaces only.
If modem_power_cycle is selected, complete the following:
Set the number of attempts for this recovery action to perform, before moving
l
to the next recovery action: