NauticaRS 5.5R Reference Guide
Parameter:
MTC:
Default:
Options:
Function:
Instructions:
Parameter:
MTC:
Default:
Options:
Function:
Instructions:
Parameter:
MTC:
Default:
Options:
Function:
Instructions:
12-4
id
id
Set at time of creation
A value from 0 to 99
Specifies the number of a filter within a profile. Using
profile numbers and IDs allows you to group filters
together and have all the filters that are enabled in a
group run consecutively using the
Enter a number from 0 to 99.
length
le
0
A valid length in bytes
Specifies the length (from the offset) to be matched.
Enter a valid length in bytes. Using this parameter allows
you to specify what portion of the packet needs to be
matched for the filter to work.
offset
of
0
A valid offset in bytes
Specifies how far into the packet the matching needs to
start.
The length parameter is how much of the packet needs
to be checked, offset specifies where in the packet to
start checking this length. It is entered in bytes.
Enter a valid offset in bytes.
andnext
parameter.
117237-E Rev.00