NauticaRS 5.5R Reference Guide
Parameter:
MTC:
Default:
Options:
Function:
Instructions:
Parameter:
MTC:
Default:
Options:
Function:
Instructions:
5-8
secure-unit
se
No
No, Yes
This parameter only works with Nautica paths.
If a remote router calls the local router and secure-unit
is set to no, the local router scans its Nautica paths for a
path that matches the name of the remote router. If a
match is found the call is connected. If no match is
found a new Nautica path is created with the name of the
remote router and the call is connected.
When secure-unit is set to yes, the name of the remote
router must match the name of an existing Nautica path.
If there is no match, the call is dropped.
Enable or disable this parameter depending on the
security systems you have implemented.
Security is also set using Password Authentication
Protocol (PAP) and Challenge Handshake
Authentication Protocol (CHAP). For more information
on PAP and CHAP, refer to Chapter 8.
advanced-manager
adv
No
No, Yes
This parameter allows more advanced features to be set.
Enable this parameter to take advantage of the more
advanced parameter settings.
For more information on advanced-manager, refer to
page
5-16.