Siemens SWT 3000 Equipment Manual page 78

Teleprotection system
Hide thumbs Also See for SWT 3000:
Table of Contents

Advertisement

Functional Description
2.11 IEC 61850
ITPC class
Status information
AlarmGen
AlarmNU
AlarmRx
LosSig
LosSyn1
LosSyn2
TxCmdCnt1
TxCmdCnt2
TxCmdCnt3
TxCmdCnt4
TxCmdCnt5
TxCmdCnt6
TxCmdCnt7
TxCmdCnt8
TxCmdCnt9
TxCmdCnt10
TxCmdCnt11
TxCmdCnt12
TxCmdCnt13
TxCmdCnt14
TxCmdCnt15
TxCmdCnt16
RxCmdCnt1
RxCmdCnt2
RxCmdCnt3
RxCmdCnt4
RxCmdCnt5
RxCmdCnt6
RxCmdCnt7
RxCmdCnt8
RxCmdCnt9
RxCmdCnt10
RxCmdCnt11
RxCmdCnt12
RxCmdCnt13
RxCmdCnt14
RxCmdCnt15
78
SPS
SWT 3000 general alarm TRUE: (Alarm is active)
SPS
SWT 3000 nun-urgent alarm TRUE: (Alarm is active)
SPS
SWT 3000 receive alarm TRUE: (Alarm is active)
SPS
Alarm situation: No signal received, indicates a channel problem
of analog communication.
Possible values:
TRUE: RXALR of PU4 LIA is active.
FALSE: RXALR of PU4 LIA is inactive.
SPS
Alarm situation: Loss of synchronism of LID-1
Indicates that there is no synchronization between the trans-
mitter and the re-ceiver, i.e., no communication is possible. Used
in case of a digital communica-tion channel.
Possible values:
TRUE: LID-1 Sync-Loss alarm is active.
FALSE: LID-1 Sync-Loss alarm is inactive.
SPS
Alarm situation: Loss of synchronism of LID-2
INS
For diagnostics: Transmitted command 1 counters.
INS
For diagnostics: Transmitted command 2 counters.
INS
For diagnostics: Transmitted command 3 counters.
INS
For diagnostics: Transmitted command 4 counters.
INS
For diagnostics: Transmitted command 5 counters.
INS
For diagnostics: Transmitted command 6 counters.
INS
For diagnostics: Transmitted command 7 counters.
INS
For diagnostics: Transmitted command 8 counters.
INS
For diagnostics: Transmitted command 9 counters.
INS
For diagnostics: Transmitted command 10 counters.
INS
For diagnostics: Transmitted command 11 counters.
INS
For diagnostics: Transmitted command 12 counters.
INS
For diagnostics: Transmitted command 13 counters.
INS
For diagnostics: Transmitted command 14 counters.
INS
For diagnostics: Transmitted command 15 counters.
INS
For diagnostics: Transmitted command 16 counters.
INS
For diagnostics: Received command 1 counters.
INS
For diagnostics: Received command 2 counters.
INS
For diagnostics: Received command 3 counters.
INS
For diagnostics: Received command 4 counters.
INS
For diagnostics: Received command 5 counters.
INS
For diagnostics: Received command 6 counters.
INS
For diagnostics: Received command 7 counters.
INS
For diagnostics: Received command 8 counters.
INS
For diagnostics: Received command 9 counters.
INS
For diagnostics: Received command 10 counters.
INS
For diagnostics: Received command 11 counters.
INS
For diagnostics: Received command 12 counters.
INS
For diagnostics: Received command 13 counters.
INS
For diagnostics: Received command 14 counters.
INS
For diagnostics: Received command 15 counters.
Smart Communication, SWT 3000 Teleprotection, Equipment Manual
C53000-G6040-C605-1, Edition 03.2020
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents