Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Preface What the consignment contains The following components are supplied with the CP 5711: ● CP 5711 communications processor ● USB cable ● 2-pin, plug-in terminal strip for external 24 V power supply Please check that the consignment you have received is complete. If it is not complete, please contact your supplier or your local Siemens office.
Page 4
→ Entry list → Entry type "Manuals / Operating Instructions" Trademarks The following and possibly other names not identified by the registered trademark sign ® are registered trademarks of Siemens AG: SIMATIC NET, HARDNET, SOFTNET, CP 1612, CP 1613, CP 5612, CP 5613, CP 5614, CP 5622...
Page 5
Preface Industry Online Support In addition to the product documentation, the comprehensive online information platform of Siemens Industry Online Support at the following Internet address: (http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo2&aktprim=99&lang= Apart from news, there you will also find: ● Project information: Manuals, FAQs, downloads, application examples etc.
Description of the device Product characteristics Properties The CP 5711 is a communications processor for connecting PCs (personal computers) or PGs (programming devices) to PROFIBUS and MPI networks. The essential properties are as follows: ● Transmission speeds up to 12 Mbps.
Page 10
Description of the device 1.1 Product characteristics Appearance The following figure shows the CP 5711 communications processor mounted on a 35 mm DIN rail: USB interface type B with USB cable LEDs DIN rail PROFIBUS interface with D-sub male connector...
Socket pin 7 is not connected. With other MPI/DP components, the P24V supply of the floating 24 V power supply may be via this pin. LTG_A Signal line A of the PROFIBUS connector. Input/output CP 5711 Operating Instructions, 02/2018, C79000-G8976-C283-05...
USB interface. IDENT (green) Flashes regularly Identification of the CP 5711 to distinguish it from other CPs in the same PG/PC Using a relevant diagnostics function in the "Communications Settings" configuration tool or the "Station Configuration Editor", you can activate these LEDs for test purposes.
After installing the communications processor, your PG/PC automatically searches for a suitable driver. 1. Follow the instructions of the Hardware Wizard of Windows. 2. Do not activate the search for drivers on the Internet. CP 5711 Operating Instructions, 02/2018, C79000-G8976-C283-05...
Uninstall the entire software package as described and recommended in the installation manual "SIMATIC NET PC Software". You will find the installation manual on the "SIMATIC NET PC Software" DVD or on the Product Support pages under the following entry ID: 77377602 (https://support.industry.siemens.com/cs/ww/en/view/77377602) CP 5711 Operating Instructions, 02/2018, C79000-G8976-C283-05...
This is the case if you only operate devices with SELV (safety extra-low voltage). WARNING EXPLOSION HAZARD Do not use any parts that show evidence of damage. WARNING EXPLOSION HAZARD DO NOT CONNECT OR DISCONNECT EQUIPMENT WHEN A FLAMMABLE OR COMBUSTIBLE ATMOSPHERE IS PRESENT. CP 5711 Operating Instructions, 02/2018, C79000-G8976-C283-05...
Page 16
First install the software before you connect the communications processor to the PG/PC, see the section Software installation (Page 13). • Activated plug and play function The plug and play function must be activated in the BIOS of your PG/PC. CP 5711 Operating Instructions, 02/2018, C79000-G8976-C283-05...
Page 17
3.1 Connecting to the PG/PC Permitted number of communications processors in the PG/PC The driver software supports a maximum of 1 CP 5711 per PG/PC. Connecting to the PG/PC Before you connect the communications processor to your PG/PC, note the following...
Note • USB module Please note: The CP 5711 is a USB module. A CP 5512, on the other hand, is connected via a CardBus interface. This means that you can only replace a CP 5512 with a CP 5711 if there is a USB connector available on the PG/PC.
Germany Conditions for the external power supply The CP 5711 can also be operated with an external power supply with 24 VDC. You require this external power in the following situations: ● The CP 5711 is operated on an external hub without its own power supply.
Page 20
Follow the steps below to disconnect the communications processor from the external power supply: 1. First, shut down any communication via the CP 5711. 2. Disconnect the USB connection from the device to the PC. 3. Disconnect the external power supply from the device.
To comply with EC Directive 94/9 (ATEX95), this enclosure must meet the requirements of at least IP54 in compliance with EN 60529. Procedure Upper DIN rail holder DIN rail Lower DIN rail holder with spring catch Spring DIN rail slider CP 5711 Operating Instructions, 02/2018, C79000-G8976-C283-05...
Page 22
The catch in the lower DIN rail holder locks onto the DIN rail. Removing the communications processor from the DIN rail To release the locking mechanism in the lower DIN rail holder, pull the DIN rail holder down. If necessary use a screwdriver or pliers. CP 5711 Operating Instructions, 02/2018, C79000-G8976-C283-05...
Compatibility during configuration If there is not yet a CP 5711 in the hardware catalog of your STEP 7 version, you can select a CP 5512 for configuration. The CP 5711 is compatible with the configuration of the CP 5512.
Page 26
Technical specifications Technical specifications of the CP 5711 Permitted ambient conditions Operating conditions Temperature (EN 60068-2-1+2) 0 ... +60°C Temperature change, maximum ≤10 K/h Relative humidity (EN 60068-2-78) 95%, 16 h at 30°C no condensation Rapid temperature change 3 h at 0°C, 3 h at 60°C...
Non Incendive / Class I / Division 2 / Groups A,B,C,D / T* and Non Incendive / Class I / Zone 2 / Group IIC / T* (T.. / T* = For detailed information on the temperature class, refer to the type plate.) CP 5711 Operating Instructions, 02/2018, C79000-G8976-C283-05...
Page 28
EN 61000-6-3. cULus Approval for Information Technology Equipment cULus Listed I. T. E. Underwriters Laboratories Inc. complying with ● UL 60950-1 (Information Technology Equipment) ● CSA C22.2 No. 60950-1-03 Report no. E115352 CP 5711 Operating Instructions, 02/2018, C79000-G8976-C283-05...
Page 29
Marking for the customs union EAC (Eurasian Conformity) Customs union of Russia, Belarus and Kazakhstan Declaration of the conformity according to the technical regulations of the customs union (TR CU) CP 5711 Operating Instructions, 02/2018, C79000-G8976-C283-05...
Dimension drawing CP 5711 front view and view from above All dimensions in millimeters CP 5711 Operating Instructions, 02/2018, C79000-G8976-C283-05...
Page 32
Dimension drawing Front view and side view of the DIN rail holder All dimensions in millimeters. CP 5711 Operating Instructions, 02/2018, C79000-G8976-C283-05...