Simulating The Signals And Changing The Signal Values - ABB OmniCore S Series Operating Manual

Robotics
Table of Contents

Advertisement

8 Handling inputs and outputs, I/O

8.4 Simulating the signals and changing the signal values

8.4 Simulating the signals and changing the signal values
Simulating the signals
A signal can be simulated.
Use the following procedure to simulate a signal:
Changing the signal values
The value of the signal can be changed.
Use the following procedure to change the value of a signal:
212
1 On the start screen, tap I/O, and then select Signals from the menu.
2 Use the Filter list or use the search box to navigate to a particular signal.
3 Tap Simulate on the context menu for the signal that is to be simulated.
The signal is changed to a simulated signal.
Note
If there is a cross connection created between two signals, changing the value
of one signal automatically changes the value of the corresponding cross
connected signal.
Note
You can change the value of a signal only if that signal is simulated. For more
details about simulating a signal see, simulating signal values.
1 On the start screen, tap I/O, and then select Signals from the menu.
2 Use the Filter list or use the search box to navigate to a particular signal.
3 To change the value of a signal:
For a digital signal, in the Value column tap on the arrow and select
value. 0 - False and 1 - True are the allowed values.
For an analog signal, in the Value column tap on the arrow. A soft
numeric keyboard is displayed. Type a value between 0 and 10 and
tap Apply.
© Copyright 20192020 ABB. All rights reserved.