M30240 Group
Figure 5.3 shows the programming algorithm flow chart.
INCREMENT ADDR
Figure 5.3:
Programming algorithm flow chart
Rev.1.00 Sep 24, 2003 Page 353 of 360
START
ADDR = FIRST LOCATION
Vcc = 6.0 V
Vpp = 12.5 V
X = 0
PROGRAM ONE PULSE OF 0.2 ms
X = X+1
X = 25?
NO
VERIFY
BYTE
PASS
PROGRAM PULSE
0.2 ms DURATION
LAST ADDR
YES
Vcc = Vpp = * 5.0 V
VERIFY
ALL BYTE
DEVICE PASSED
YES
VERIFY
BYTE
PASS
FAIL
DEVICE
FAILED
* 4.5 < Vcc = Vpp < 5.5 V
=
=
EPROM version
DEVICE
FAIL
FAILED