M30240 Group
Selecting Sample and hold
b7
0 0 0
Setting A-D control register 0 and A-D control register 1
b7
0
0
0
0
Note: Rewrite the analog input pin select bit after changing A-D operation mode.
Setting A-D conversion start flag
b7
1
Reading conversion result
(b15)
b7
Figure 2.80: Set-up procedure of one-shot mode
Rev.1.00 Sep 24, 2003 Page 234 of 360
b0
A-D control register 2 [Address 03D4
1
ADCON2
A-D conversion method select bit
1 : With sample and hold
b0
A-D control register 0 [Address 03D6
ADCON0
Analog input pin select bit (Note)
b2 b1 b0
0 0 0 : AN
is selected
0
0 0 1 : AN
is selected
1
0 1 0 : AN
is selected
2
0 1 1 : AN
is selected
3
1 0 0 : AN
is selected
4
1 0 1 : AN
is selected
5
1 1 0 : AN
is selected
6
1 1 1 : AN
is selected
7
One-shot mode is selected (Note)
Trigger select bit
0 : Software trigger
A-D conversion start flag
0 : A-D conversion disabled
Frequency select bit 0
0 : f
/4 is selected
AD
1 : f
/2 is selected
AD
b0
A-D control register 0 [Address 03D6
ADCON0
A-D conversion start flag
1 : A-D conversion started
Start A-D conversion
Stop A-D conversion
A-D register 0
A-D register 1
(b8)
A-D register 2
b0
b7
b0
A-D register 3
A-D register 4
A-D register 5
A-D register 6
A-D register 7
Eight low-order bits of A-D conversion result
During 10-bit mode
Two high-order bits of A-D conversion result
During 8-bit mode
When read, the content is indeterminate
]
16
b7
b0
A-D control register 1 [Address 03D7
]
16
0
0
1
0
ADCON1
Invalid in one-shot mode
A-D operation mode select bit 1 (Note)
0 (Must always be "0" in one-shot mode)
8/10-bit mode select bit
0 : 8-bit mode
1 : 10-bit mode
Frequency select bit 1
0 : f
AD
1 : f
AD
Vref connect bit
1 : Vref connected
Reserved bits. Always set to "0"
]
16
[Address 03C1
, 03C0
] AD0
16
16
[Address 03C3
, 03C2
] AD1
16
16
[Address 03C5
, 03C4
] AD2
16
16
[Address 03C7
, 03C6
] AD3
16
16
[Address 03C9
, 03C8
] AD4
16
16
[Address 03CB
, 03CA
] AD5
16
16
[Address 03CD
, 03CC
] AD6
16
16
[Address 03CF
, 03CE
] AD7
16
16
A-D Converter
]
16
/2 or f
/4 is selected
AD
is selected