3. POSITIONING SIGNALS
3.2.2

Control change registers

Name
Axis 1
D641, D640 D643, D642 D645, D644 D647, D646 D649, D648 D651, D650 D653, D652 D655, D654
Axis 9
D657, D656 D659, D658 D661, D660 D663, D662 D665, D664 D667, D666 D669, D668 D671, D670
JOG speed
setting
Axis 17
register
D673, D672 D675, D674 D677, D676 D679, D678 D681, D680 D683, D682 D685, D684 D687, D686
Axis 25
D689, D688 D691, D690 D693, D692 D695, D694 D697, D696 D699, D698 D701, D700 D703, D702
Unit
Item
Setting range
JOG speed
1 to 600000000
The control change data storage area stores JOG operation speed data.
Table 3.1 Control Change Data Storage Area List
Axis 2
Axis 3
Axis 10
Axis 11
Axis 18
Axis 19
Axis 26
Axis 27
POINT
• Since a current value change/speed change is made commandable by the
CHGA/CHGV instruction, there are no current value change registers/speed
change registers.
(1) JOG speed setting registers (D640+2n) ..... Data from SCPU to PCPU
(a) These registers store JOG speed for JOG operation.
(b) The JOG speed setting ranges are indicated below.
mm
Unit
Setting range
-2
×10
mm/min 1 to
600000000
(c) The JOG speed is the value stored in the JOG speed setting registers on
the leading edge (OFF to ON) of the JOG start signal.
The JOG speed cannot be changed if data is changed during JOG
operation.
(d) Refer to Section 7.19 for details of JOG operation.
Axis 4
Axis 5
Axis 12
Axis 13
Axis 20
Axis 21
Axis 28
Axis 29
inch
Unit
Setting range
1 to
-3
×10
inch/min
2147483647
3 − 41
Axis 6
Axis 7
Axis 14
Axis 15
Axis 22
Axis 23
Axis 30
Axis 31
degree
Unit
Setting range
-3
×10
degree
1 to
10000000
/min
Axis 8
Axis 16
Axis 24
Axis 32
PULSE
Unit
PLS/s