Siemens Simovert Masterdrives Compendium page 1326

Motion control
Hide thumbs Also See for Simovert Masterdrives:
Table of Contents

Advertisement

Parameter
Description
U393
Function parameter for entering the wobble amplitude as
Wobb Amplitude
a relation to the input signal amount (setpoint)
2393
U394
Function parameter for entering the frequency of the
Wobb Freq
wobble signal
2394
U395
Function parameter for entering the phase shift of the
Wobb Phase Shift
wobble signal compared to the master synchronizing
signal. At a value of 360°, the synchronizing signal is not
2395
observed; coasting wobbling takes place.
U396
Function parameter for entering the amount of the
Wobb P-Step
negative P step as a percentage of the wobble amplitude
2396
U397
Function parameter for entering the amount of the positive
Wobb P-Step
P step as a percentage of the wobble amplitude.
2397
U398
Function parameter for entering the time portion of the
Wobb Sampl Ratio
increasing edge of the wobble signal
2398
n399
Visualization parameter for displaying the wobble signal.
Wobb Gen Outp
2399
U400*
Parameter for selecting the double word connector for the
S.ConnAnaDel_1
1st analog delay element.
2400
U401*
Parameter for entering the delay cycles of the 1st analog
AnaDelayEl_1_T
delay element
2401
Siemens AG
6SE7087-6QX70 (Edition AL )
SIMOVERT MASTERDRIVES Compendium Motion Control
Data
Read/write
index1: 0,00
Menus:
Min: 0,00
- Parameter menu
Max: 20,00
+ Free blocks
Unit: %
- Upread/free access
Indices: 4
Changeable in:
,FDS
- Ready to switch on
Type: O2
- Operation enabled
index1: 60,0
Menus:
Min: 0,1
- Parameter menu
Max: 120,0
+ Free blocks
Unit: 1/min
- Upread/free access
Indices: 4
Changeable in:
,FDS
- Ready to switch on
Type: O2
- Operation enabled
index1: 360
Menus:
Min: 0
- Parameter menu
Max: 360
+ Free blocks
Unit: ° (alt)
- Upread/free access
Indices: 4
Changeable in:
,FDS
- Ready to switch on
Type: O2
- Operation enabled
index1: 0,00
Menus:
Min: 0,00
- Parameter menu
Max: 100,00
+ Free blocks
Unit: %
- Upread/free access
Indices: 4
Changeable in:
,FDS
- Ready to switch on
Type: O2
- Operation enabled
index1: 0,00
Menus:
Min: 0,00
- Parameter menu
Max: 100,00
+ Free blocks
Unit: %
- Upread/free access
Indices: 4
Changeable in:
,FDS
- Ready to switch on
Type: O2
- Operation enabled
index1: 50
Menus:
Min: 0
- Parameter menu
Max: 100
+ Free blocks
Unit: %
- Upread/free access
Indices: 4
Changeable in:
,FDS
- Ready to switch on
Type: O2
- Operation enabled
Dec.Plc.: 1
Menus:
Unit: %
- Parameter menu
Indices: -
+ Free blocks
Type: I2
- Upread/free access
Init: 0
Menus:
Unit: -
- Parameter menu
Indices: -
+ Free blocks
Type: L2 ,K
- Upread/free access
,K
Changeable in:
- Ready to switch on
- Operation enabled
Init: 0
Menus:
Min: 0
- Parameter menu
Max: 32
+ Free blocks
Unit: -
- Upread/free access
Indices: -
Changeable in:
Type: O2
- Ready to switch on
- Operation enabled
166

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents