Without Function - Siemens Simovert Masterdrives Compendium

Motion control
Hide thumbs Also See for Simovert Masterdrives:
Table of Contents

Advertisement

Parameter
Description
P254*
At filter characteristic 1 (P256=1):
Filter Frequency
Resonant frequency of the band-stop filter.
254
Harmonics of exactly this frequency are completely
eliminated by the band-stop filter.
The extent to which neighbouring frequencies are
weakened depends on the quality/selectivity of band-stop
filter P253.
At filter characteristic 2 (P256=2):
Key frequency (-3dB) of the low-pass filter. At this
frequency the amplitude is weakened to 70% (=3dB).
r255
Visualization parameter for displaying the torque setpoint
Torq(set,n-Reg)
at the output of the speed controller.
255
P256*
The parameter defines the filter characteristic.
Filter Character
Value = 0: Enabled
256
Value = 1: Band-stop
Value = 2: Low pass
Value = 3: extended band-stop
Further values for future use !
P257*
Further essential quantities of the filter can be preset via
Filter Adjust1
this parameter depending on the filter characteristic.
257
Filter characteristic 1 (band-stop):
The remaining amplitude at filter frequency can be preset
via this parameter. In view of the phase response, it can
be worthwhile not to suppress this amplitude completely.
Filter characteristic 2 (low-pass):

Without function.

P258*
Further essential quantities of the filter can be preset via
Filter Adjust2
this parameter depending on the filter characteristic.
258
P259
Function parameter for entering the dead time for the filter
Tdead RefModel
of the reference model. The parameter is only effective if
the structure "PI controller with reference model" has
259
been selected in P238.
In function diagram 360a.3
P260*
BICO parameter for selecting the connector from which
S.Torq (set)
the torque setpoint is to be read in during "Master drive"
operating mode.
260
Siemens AG
6SE7087-6QX70 (Edition AL )
SIMOVERT MASTERDRIVES Compendium Motion Control
Data
Read/write
index1: 50,0
Menus:
Min: 1,0
- Parameter menu
Max: 500,0
+ Control/gating unit
Unit: Hz
+ Speed control
Indices: 3
- Upread/free access
Type: O2
Changeable in:
- Ready to switch on
- Operation enabled
Dec.Plc.: 1
Menus:
Unit: Nm
- Parameter menu
Indices: -
+ Control/gating unit
Type: I4
+ Speed control
- Upread/free access
index1: 1
Menus:
Min: 0
- Parameter menu
Max: 7
+ Control/gating unit
Unit: -
+ Speed control
Indices: 3
- Upread/free access
Type: O2
Changeable in:
- Ready to switch on
- Operation enabled
index1: 0,000
Menus:
Min: 0,000
- Parameter menu
Max: 200,000
+ Control/gating unit
Unit: %
+ Speed control
Indices: 3
- Upread/free access
Type: I4
Changeable in:
- Ready to switch on
- Operation enabled
index1:
Menus:
100,000
- Parameter menu
Min: 0,000
+ Control/gating unit
Max: 200,000
+ Speed control
Unit: %
- Upread/free access
Indices: 3
Changeable in:
Type: I4
- Ready to switch on
- Operation enabled
index1: 2,0
Menus:
Min: 0,0
- Parameter menu
Max: 4,9
+ Control/gating unit
Unit: -
+ Speed control
Indices: 4
- Upread/free access
,FDS
Changeable in:
Type: O2
- Ready to switch on
- Operation enabled
index1: 153
Menus:
Unit: -
- Parameter menu
Indices: 2
+ Control/gating unit
,BDS
+ Speed control
Type: L2 ,K
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
43

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents