Siemens Simovert Masterdrives Compendium page 1297

Motion control
Hide thumbs Also See for Simovert Masterdrives:
Table of Contents

Advertisement

Parameter
Description
U133
Function parameter for entering the fixed setpoint for
FSetp DConnLmt
limiter 1 (2 word).
2133
U134*
BICO parameter for selecting the connector for limiter 1 (2
S.DConnLimitr
word).
2134
U135
Function parameter for entering the fixed setpoint for the
FSetpConnLmtMon1
1st limit-value monitor with smoothing (1 word).
2135
U136*
BICO parameter for selecting the connector for the 1st
S.ConnLmtMon1
limit-value monitor with smoothing (1 word).
2136
U137
Function parameter for entering the smoothing time
SmConnLmtMon1
constants of the 1st limit-value monitor with smoothing (1
word).
2137
U138
Function parameter for entering the hysteresis of the 1st
HysConnLmtMon1
limit-value monitor with smoothing (1 word).
2138
U139*
Function parameters for entering the mode of the 1st limit-
ModeConnLmtMon1
value monitors with smoothing (1 word).
2139
U140
Function parameter for entering the fixed setpoint for the
FSetpConnLmtMon1
2nd limit-value monitor with smoothing (1 word).
2140
U141*
BICO parameter for selecting the connector for the 2nd
S.ConnLmtMon2
limit-value monitor with smoothing (1 word).
2141
Siemens AG
6SE7087-6QX70 (Edition AL )
SIMOVERT MASTERDRIVES Compendium Motion Control
Data
Read/write
index1:
Menus:
100,00
- Parameter menu
Min: -200,00
+ Free blocks
Max: 200,00
- Upread/free access
Unit: %
Changeable in:
Indices: 4
- Ready to switch on
,FDS
- Operation enabled
Type: I4
index1: 509
Menus:
Unit: -
- Parameter menu
Indices: 3
+ Free blocks
Type: L2 ,K
- Upread/free access
,K
Changeable in:
- Ready to switch on
- Operation enabled
Init: 0,00
Menus:
Min: -200,00
- Parameter menu
Max: 200,00
+ Free blocks
Unit: %
- Upread/free access
Indices: -
Changeable in:
Type: I2
- Ready to switch on
- Operation enabled
index1: 0
Menus:
Unit: -
- Parameter menu
Indices: 2
+ Free blocks
Type: L2 ,K
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
Init: 0
Menus:
Min: 0
- Parameter menu
Max: 10000
+ Free blocks
Unit: ms
- Upread/free access
Indices: -
Changeable in:
Type: O2
- Ready to switch on
- Operation enabled
Init: 0,00
Menus:
Min: 0,00
- Parameter menu
Max: 199,99
+ Free blocks
Unit: %
- Upread/free access
Indices: -
Changeable in:
Type: O2
- Ready to switch on
- Operation enabled
Init: 0
Menus:
Min: 0
- Parameter menu
Max: 2
+ Free blocks
Unit: -
- Upread/free access
Indices: -
Changeable in:
Type: O2
- Ready to switch on
Init: 0,00
Menus:
Min: -200,00
- Parameter menu
Max: 200,00
+ Free blocks
Unit: %
- Upread/free access
Indices: -
Changeable in:
Type: I2
- Ready to switch on
- Operation enabled
index1: 0
Menus:
Unit: -
- Parameter menu
Indices: 2
+ Free blocks
Type: L2 ,K
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
137

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents