Parameter
Description
U615*
Table configuration:
TableConfig
The parameter determines how the interpolation points
are distributed to the tables, or how many tables are
2615
selectable.
Use can be made of
-> one table with 400 interpolation points (parameter value
= 0)
or
-> two tables each with 200 interpolation points
(parameter value = 1)
or
-> four tables each with 100 interpolation points
(parameter value = 2)
or
-> eight tables each with 50 interpolation points
(parameter value = 3)
or
-> up to eight tables with as many interpolation points of
the possible 400 as desired (parameter value = 4).
Parameter values 10 to 14 for special applications; only
after consultation with the Applications Center, Erlangen.
The parameter can be changed only if the "cam"
synchronism function (U603, U657 in function diagram
835.6) is not selected!
Changing the configuration sets the status (U617) of the
table to "untested" or "non-existent"
In function diagram 839.6
Siemens AG
6SE7087-6QX70 (Edition AL )
SIMOVERT MASTERDRIVES Compendium Motion Control
Data
Read/write
Init: 1
Menus:
Unit: -
- Parameter menu
Indices: -
+ Technology
Type: L2
+ Synchronism
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
203