Siemens Simovert Masterdrives Compendium page 1325

Motion control
Hide thumbs Also See for Simovert Masterdrives:
Table of Contents

Advertisement

Parameter
Description
U385*
BICO parameter for selecting a parameter from which a
S.T (total1)
torque value for the torque addition block is to be read in.
2385
U386*
BICO parameter for selecting a parameter from which a
S.T (total2)
torque value for the torque addition block is to be read in.
2386
U387*
BICO parameter for selecting a parameter from which a
S.T (total3)
torque value for the torque addition block is to be read in.
2387
U388*
Moment of inertia in % (for calculating the acceleration
Mom_Inertia.J
torque)
2388
U389*
Selection of calculation of the acceleration torque:
Ber.M(accel)
0: with scaled moment of inertia
1: with moment of inertia in %
2389
U390*
BICO parameter for selecting the connector for the input
S.WobbSetp Unwo
of the wobble generator
2390
U391*
BICO parameter for selecting the binector for the master
S.Wobb SyncInp
synchronizing signal of the wobble generator
2391
U392*
BICO parameter for selecting the binector for wobble
S.Wobb Rel
release
2392
Siemens AG
6SE7087-6QX70 (Edition AL )
SIMOVERT MASTERDRIVES Compendium Motion Control
Data
Read/write
index1: 0
Menus:
Unit: -
- Parameter menu
Indices: 2
+ Control/gating unit
,BDS
+ Current control
Type: L2 ,K
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
index1: 0
Menus:
Unit: -
- Parameter menu
Indices: 2
+ Control/gating unit
,BDS
+ Current control
Type: L2 ,K
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
index1: 0
Menus:
Unit: -
- Parameter menu
Indices: 2
+ Control/gating unit
,BDS
+ Current control
Type: L2 ,K
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
index1:
Menus:
100,00
- Parameter menu
Min: 0,00
+ Control/gating unit
Max: 200,00
+ Current control
Unit: %
- Upread/free access
Indices: 2
Changeable in:
Type: O2
- Ready to switch on
- Operation enabled
Init: 0
Menus:
Min: 0
- Parameter menu
Max: 1
+ Control/gating unit
Unit: -
+ Current control
Indices: -
- Upread/free access
Type: O2
Changeable in:
- Ready to switch on
Init: 0
Menus:
Unit: -
- Parameter menu
Indices: -
+ Free blocks
Type: L2 ,K
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
Init: 0
Menus:
Unit: -
- Parameter menu
Indices: -
+ Free blocks
Type: L2 ,B
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
Init: 0
Menus:
Unit: -
- Parameter menu
Indices: -
+ Free blocks
Type: L2 ,B
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
165

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents