Parameter
Description
P261*
BICO parameter for selecting the connector from which
S.Torq(conseq)
the torque setpoint is to be read in during "Slave drive"
operating mode.
261
P262*
BICO parameter for selecting the connector from which
S.Torque(add)
the additional setpoint for the torque is to be read in. The
additional setpoint is added to the setpoint of the torque
262
both in "Master drive" and "Slave drive" operating mode.
P263*
Function parameter for entering the fixed setpoint for the
FSetpTorq(Lim1)
upper torque limit. The parameter value entered relates to
the reference torque entered in P354.
263
IMPORTANT. Only positive values are permissible!
In function diagram 370.1
P264*
Function parameter for entering the fixed setpoint for the
FSetpTorq(Lim2)
lower torque limit. The parameter value entered relates to
the reference torque entered in P354.
264
IMPORTANT: Only negative values are permissible!
In function diagram 370.1
P265*
BICO parameter for selecting the connector from which
S.Torq(Limit1)
the upper limit for the torque is to be read in.
265
P266*
BICO parameter for selecting the connector from which
S.Torq(Limit2)
the lower limit for the torque is to be read in.
266
P267*
BICO parameter for selecting the connector from which
S.Torque(add3)
the supplementary setpoint for the torque is to be read in.
The supplementary setpoint is added to the limited
267
setpoint of the torque, i.e the addition takes place behind
the limitation of the torque.
r269
Visualization parameter for displaying the torque setpoint
Torq (set, Lim)
after limitation.
269
Siemens AG
6SE7087-6QX70 (Edition AL )
SIMOVERT MASTERDRIVES Compendium Motion Control
Data
Read/write
index1: 0
Menus:
Unit: -
- Parameter menu
Indices: 2
+ Control/gating unit
,BDS
+ Speed control
Type: L2 ,K
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
index1: 0
Menus:
Unit: -
- Parameter menu
Indices: 2
+ Control/gating unit
,BDS
+ Speed control
Type: L2 ,K
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
index1: 100,0
Menus:
Min: -200,0
- Parameter menu
Max: 200,0
+ Control/gating unit
Unit: %
+ Speed control
Indices: 4
- Upread/free access
,FDS
Changeable in:
Type: I2
- Ready to switch on
- Operation enabled
index1: -
Menus:
100,0
- Parameter menu
Min: -200,0
+ Control/gating unit
Max: 200,0
+ Speed control
Unit: %
- Upread/free access
Indices: 4
Changeable in:
,FDS
- Ready to switch on
Type: I2
- Operation enabled
index1: 170
Menus:
Unit: -
- Parameter menu
Indices: 2
+ Control/gating unit
,BDS
+ Speed control
Type: L2 ,K
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
index1: 171
Menus:
Unit: -
- Parameter menu
Indices: 2
+ Control/gating unit
,BDS
+ Speed control
Type: L2 ,K
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
index1: 0
Menus:
Unit: -
- Parameter menu
Indices: 2
- Upread/free access
,BDS
Changeable in:
Type: L2 ,K
- Ready to switch on
- Operation enabled
Dec.Plc.: 1
Menus:
Unit: Nm
- Parameter menu
Indices: -
+ Control/gating unit
Type: I4
+ Speed control
- Upread/free access
44