Parameter
Description
P781*
Function parameter for setting a delay time for various
Fault Delay
faults.
Special case: Value 101.0 means that the fault is never
781
triggered.
Index 1: Ext. fault 1
Index 2: Ext. fault 2
Index 4:
Index 5:
Index 6:
Index 7:
Index 8:
Index 9:
Index 10:
Index 11: SCom1 telegram failure
Index 12: SCom2 telegram failure
Index 13: CB/TB telegram failure
Index 14: 2nd CB telegram failure
Index 15: SCB telegram failure
Index 16: SLB telegram failure
Index 17:
Index 18:
Index 19:
Index 20:
r782
Visualization parameter for displaying the times at which
Trip Time
the last 8 faults occurred. The current status of the
operating-hours counter (r825) is displayed.
782
Index 1: Day of the
Index 2: Hour of the
Index 3: Second of the 1st fault trip
Indices 4 to 6:
Indices 7 to 9:
Indices 10 to 12:
Indices 13 to 15:
Indices 16 to 18:
Indices 19 to 21:
Indices 22 to 24:
Further details for describing the fault trips are contained
in r947, r949, P952. The fault memory is deleted with the
help of P952.
P788
Function parameter for entering the comparison value for
V DCLink(Thresh)
the DC link voltage. If the DC link voltage drops due to
voltage dips in the power system, the drive can still be
788
brought to a guided standstill if the voltage falls below the
set threshold. A turn-off due to undervoltage is prevented.
P790*
BICO parameter for selecting the connector from which
S.Setp
the setpoint is to be read in for detecting deviation of the
actual value from the setpoint. A deviation is indicated in
790
status word 1, bit 8.
P791*
BICO parameter for selecting the connector from which
S.ActV
the actual value is to be read in for detecting a deviation
of the actual value from the setpoint. A deviation is
791
indicated in status word 1, bit 8.
Siemens AG
6SE7087-6QX70 (Edition AL )
SIMOVERT MASTERDRIVES Compendium Motion Control
1st (last) fault trip
1st fault trip
2nd fault trip
3rd fault trip
4th fault trip
5th fault trip
6th fault trip
7th fault trip
8th (oldest) fault trip
Data
Read/write
index1: 0,0
Menus:
Min: 0,0
- Parameter menu
Max: 101,0
+ Diagnostics
Unit: s
+ Faults/warnings
Indices: 20
- Upread/free access
Type: O2
Changeable in:
- Ready to switch on
- Operation enabled
Dec.Plc.: 0
Menus:
Unit: -
- Parameter menu
Indices: 24
+ Diagnostics
Type: O2
+ Faults/warnings
- Drive setting
- Upread/free access
Init: 800
Menus:
Min: 0
- Parameter menu
Max: 1000
+ Diagnostics
Unit: V
+ Faults/warnings
Indices: -
- Upread/free access
Type: O2
Changeable in:
- Ready to switch on
- Operation enabled
Init: 150
Menus:
Unit: -
- Parameter menu
Indices: -
+ Diagnostics
Type: L2 ,K
+ Messages/displays
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
Init: 91
Menus:
Unit: -
- Parameter menu
Indices: -
+ Diagnostics
Type: L2 ,K
+ Messages/displays
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
103