Siemens Simovert Masterdrives Compendium page 1146

Motion control
Hide thumbs Also See for Simovert Masterdrives:
Table of Contents

Advertisement

Status of the table last checked
0 = No error
1 = Number of support points = 0
2 = Support value > Table width
3 = Ascending sequence of support
values for X axis violated
1 = U630 defective
2 = U631 defective
3 = U640 defective
4 = U641 defective
5 = U632 defective
6 = U633 defective
7 = U642 defective
8 = U643 defective
1...50 = Index .01 ... .50 of the
last error-free support
values
T H Z E
n668.x
Status, table
KK0810
Status, table 1
n668.1
KK0811
Status, table 2
n668.2
KK0840
Status, table 3
n668.3
KK0841
Status, table 4
n668.4
KK0842
Status, table 5
n668.5
KK0843
Status, table 6
n668.6
KK0844
Status, table 7
n668.7
KK0845
Status, table 8
n668.8
[836.1]
<1> U617.x = 0 :
Table OK
U617.x = 1 :
Table has been changed and not yet checked or
the check found an error (error status in n668.x)
U617.x = 2 :
Check command for table; if the table is OK,
the value "0" is automatically entered in U617as an ack-
nowledgement; if the table is not OK, U617 jumps back
to the value "1"
U617.x =10:
Table not present
<2> Can only be changed when curve cam is not selected
1
2
Technology option
Mode of Operation Synchronism - Cam 8 tables with 50 points each
Table width X_max
U620.01 (4096) for Table 1
U620.02 (4096) for Table 2
U620.03 (4096) for Table 3
U620.04 (4096) for Table 4
Number of support points X_max 1...50
U620.05 (4096) for Table 5
U629.1 (0) = Table 1
U620.06 (4096) for Table 6
<2>
U629.2 (0) = Table 2
U620.07 (4096) for Table 7
U629.3 (0) = Table 3
U620.08 (4096) for Table 8
U629.4 (0) = Table 4
U629.5 (0) = Table 5
U629.6 (0) = Table 6
U629.7 (0) = Table 7
U629.8 (0) = Table 8
Check table 0...2
<2>
U617.01 Table 1
<1>
U617.02 Table 2
Y4
U617.03 Table 3
Y3
U617.04 Table 4
U617.05 Table 5
Y2
U617.06 Table 6
Y1
U617.07 Table 7
U617.08 Table 8
X
Cam input
X1-X50
U630.1-50
U631.1-50
U640.1-50
U641.1-50
U632.1-50
U633.1-50
Support point, X axis:
31
0 ... 2
-1 [LU]
<2>
3
4
<2>
31
0...2
-1 LU
Cam
Relative
Y
(U616 = xxx1)
U620, U629
Absolute
4
(U616 = xxx0)
3
2
1
X
X1 X2 X3 X4
X_max
Table 1
Y1-Y50
Table 2
X51-X100
Y51-Y100
Table 3
X101-X150
Y101-Y150
Table 4
X151-X200
Y151-Y200
Table 5
X201-X250
Table 6
X251-X300
Table 7
X301-X350
U642.1-50
Table 8
X351-X400
U643.1-50
Table configuration
0 = One table with 400 points (Table 1 {X1-X400})
1 = Two tables with 200 points each (Tables 1 {X1-X200} and 2 {X201-X400})
2 = Four tables with 100 points each (Tables 1, 2, 3, and 4)
3 = Eight tables with 50 points each (Tables 1 ... 8)
4 = Variable with up to 8 tables with a total of 400 support values
5
V2.5
fp_mc_839d_e.vsd
U650 (0)
.01
B
.02
B
.03
B
2 2 2
0
1
2
0
1
2
3
4
5
6
7
U635.1-50
n644
U636.1-50
U645.1-50
Support points, Y axis:
U646.1-50
31
-2
... 2
Y201-Y250
<2>
U637.1-50
Y251-Y300
U638.1-50
Y301-Y350
U647.1-50
Y351-Y400
U648.1-50
<2>
U615. (1) = 3
6
7
Function diagram
MASTERDRIVES MC
01.07.03
U953.33 = ___(20)
(for sheet [834] ...[843])
see [331.3]
[TABLE_NO] 0 = Table 1
1 = Table 2
2 = Table 3
3 = Table 4
4 = Table 5
5 = Table 6
6 = Table 7
7 = Table 8
Cam
output
[835.4]
Y
Current table number 1...8
31
-1 [LU]
8
- 839d -

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents