Parameter
Description
U481*
Function parameter for entering the word length of the
Trace DoubleWord
connector indicated in U2480 to be recorded by the trace
function.
2481
It is only possible to change the parameter if the trace
function is not active (U488 = 0). If the parameter is
changed, an output of previously recorded values for
concerned channels is no longer possible.
Parameter values:
0 = Word (16 bit)
1 = Double word (32 bit)
Indices: Index = channel number
U482*
Function parameter for entering the sampling time with
TraceSampleTime
which the trace values are to be recorded in integral
multiples of the basic sampling time of the trace function.
2482
Indices: Index = channel number
U483*
BICO parameter for selecting the connector to be used by
S.TriggerInput
the trace function as a trigger
2483
Indices: Index = channel number
U484
Function parameter for entering the trigger threshold. The
TriggerThresh
parameter value has to be entered in the format of a
double-word connector. If bit trigger (U485 <> 16) is set,
2484
only the parameter values 0 and 1 are permissible.
Indices: Index = channel number
U485*
Function parameter for entering the position of the bit to
TriggerBitNo.
be triggered (in the case of bit trigger). A bit trigger can
only be set if the trigger threshold (U484) has the values 0
2485
or 1. If a bit trigger is set, the trigger condition (U486) is
automatically adjusted to 1 (trigger if trigger input = trigger
threshold).
Parameter values:
0 to 15: Position of the bit (bit trigger)
16: No bit trigger
Indices: Index = channel number
Siemens AG
6SE7087-6QX70 (Edition AL )
SIMOVERT MASTERDRIVES Compendium Motion Control
Data
Read/write
index1: 0
Menus:
Min: 0
- Parameter menu
Max: 1
+ Diagnostics
Unit: -
+ Trace
Indices: 8
- Upread/free access
Type: O2
Changeable in:
- Power section definition
- Board configuration
- Drive setting
- Ready to switch on
- Operation enabled
index1: 1
Menus:
Min: 1
- Parameter menu
Max: 200
+ Diagnostics
Unit: -
+ Trace
Indices: 8
- Upread/free access
Type: O2
Changeable in:
- Power section definition
- Board configuration
- Drive setting
- Ready to switch on
- Operation enabled
index1: 0
Menus:
Unit: -
- Parameter menu
Indices: 8
+ Diagnostics
Type: L2 ,K
+ Trace
,K
- Upread/free access
Changeable in:
- Power section definition
- Board configuration
- Drive setting
- Ready to switch on
- Operation enabled
index1: 0
Menus:
Min: -
- Parameter menu
2147483647
+ Diagnostics
Max:
+ Trace
2147483647
- Upread/free access
Unit: -
Changeable in:
Indices: 8
- Power section definition
Type: I4
- Board configuration
- Drive setting
- Ready to switch on
- Operation enabled
index1: 16
Menus:
Min: 0
- Parameter menu
Max: 16
+ Diagnostics
Unit: -
+ Trace
Indices: 8
- Upread/free access
Type: O2
Changeable in:
- Power section definition
- Board configuration
- Drive setting
- Ready to switch on
- Operation enabled
178