Adaption of acceleration/deceleration time
<4>
U329 (1)
K
Bypass ramp-function generator (y:=x)
U328 (0)
B
Quick stop comfort RGen
U338 (0)
Ramp-function generator input
B
U320 (0)
KK
0
0
[790.8] (RGen output)
KK0571
1
1
0 %
U321 (0)
(Freeze y)
B
Stop RGen
U322 (0)
Bring RGen to a standstill
B
U323 (0)
Ramp-function generator setting value
KK
U324 (0)
Set RGen (y = setting value)
B
U327 (0) Operating mode for rounding
0: Final rounding does not act upon sudden reduction
of the input value during acceleration
1: Rounding always acts (except when output limitation
has responded). If there is a sudden reduction of the
input value, overshooting can occur.
Selection of function data set
for comfort ramp-function generator
<1> At U328 = 552 the RGen only acts once in each case after enabling (^ edge)
<2> Effective accel.time: Tup_eff = Tup * adaption factor + (AR/2 + ER/2)/adaption factor
Effective decel.time: Tdn_eff = Tdn * adaption factor + (AR/2 + ER/2)/adaption factor
(If adaption is used, the jerk remains the same)
<3> Ramp-function generator is tracked when a limitation responds (y:=RGen output)
<4> Rounding and adaption do not act with the 'min' or 'h' unit for accel./decel. time
<5> Rounding also acts during a zero passage
1
2
Free blocks
Comfort ramp-function generator
Acceleration time
Unit for accel. time
0.0...999.9
U330.F (10.0)
U331.F (0)
0.2 %
0 s
0
1
<1> <6>
<6>
0...3599640.0 s
n339.01
n326
KK0570
Tup
Tup
y
100 %
0
x
0 %
1
-100 %
y
AR
Tup_eff <2>
Rounding Mode
U345
U325 (1)
.01
B (92)
B
.02
B (93)
3
4
Deceleration time
Unit for decel. time
0.0...999.9
U332.F (10.0)
U333.F (0)
0 s
0
1
Quick stop time
0.0...999.9 s
U337 (10.0)
0
1
n339.02
Tdn
Tdn
Comfort ramp-function generator
<5>
ER
AR
ER
AR
ER
AR
Tdn_eff <2>
1 = Enable ramp-function generator
0 = Set ramp-function generator to zero
POWER ON
[710.5]
5
V2.5
fp_mc_790_e.vsd
Initial rounding
Final rounding
0.00...10.00 s
0.00...10.00 s
U334.F (0.00)
U335.F (0.00)
{70 µs}
0 s
0 s
Without rounding and adaption
0
1
0
1
{130 µs}
With rounding and adaption
0.00...+200.00 %
U342 (100.00)
KK0573
Output limitation
-1
KK0574
AR
ER
B+
y
B-
t
<3>
Track RGen
(with this acceleration time
Rated acceleration time
dy/dt = 100 %)
0.01 ... 300.00 s
U336 (0.01)
ER
dy/dt
t
y = 0
B0550
Ramp-function generator output = 0
y = x
B0551
Acceleration finished
y = 0
<1>
R
Q
B0552
<6>
0 = RGen initial runs
1
S
Priority:
<6> Priority of control commands:
1. S (SET)
1. Set RGen to zero
2. R (RESET)
2. Quick stop comfort RGen
3. Set ramp-function generator
4. Bypass RGen (y:=x)
5. Bring RGen to a standstill
6. Stop ramp-function generator
6
7
Function diagram
MASTERDRIVES MC
08.01.02
U951.51 = ___(20)
U343 (573)
B+
KK
U344 (574)
B-
KK
n340
KK0571
RGen output
n341
KK0572
8
- 790 -