Siemens Simovert Masterdrives Compendium page 1335

Motion control
Hide thumbs Also See for Simovert Masterdrives:
Table of Contents

Advertisement

Parameter
Description
U462*
Index 1
Sync Window
Internal window [F1]
2462
Index 2
External window [F2]
F1 < synchronizing difference < F2:
If the synchronizing difference lies within the external
window, synchronizing is effected in the shortest way.
Synchronizing difference > F2:
If the synchronizing difference lies outside the outer
window, synchronizing is effected according to the
selected mode in a certain direction.
Synchronizing difference < F1:
If the synchronizing difference lies within the inner
window, no synchronizing movement takes place,
synchronous message is effected immediately (B0811)
and the established synchronizing difference is calculated
with the displacement. At window size 0, the internal
window is deselected (only external window still active).
U463*
Index 1:
S.Gl.RLEnable
Binector source for release speed positive
2463
Index 2:
Binector source for release speed negative
U464*
Index 1:
S.Gl.EnableSet
Binector source for release displacement angle setting
2464
Index 2:
Binector source for adding remaining distance to current
displacement
n465
Index 1:
DispSpeed
Current adjustment speed in percent referred to U697.2
[in function diagram 841]
2465
Index 2:
Current adjustment speed including v_inching in percent
referred to U607 [in function diagram 841]
n466
Visualization parameter for offset angle setting
Displ_Act_Resid
[in function diagram 841]
2466
Index 1: Remaining offset path (KK827)
Index 2: Current offset (KK812)
U467*
Parameter for position correction
PosCorrection
Function diagram [843.5]
2467
Index 1: Correction speed [1000LU/min]
Index 2: Acceleration [1000LU/sec^2]
U468*
Speed adjustment in percent for U467.1
PosCorrVFactor
2468
Siemens AG
6SE7087-6QX70 (Edition AL )
SIMOVERT MASTERDRIVES Compendium Motion Control
Data
Read/write
index1: 0
Menus:
Min: 0
- Parameter menu
Max:
+ Technology
2147483647
+ Synchronism
Unit: -
- Upread/free access
Indices: 2
Changeable in:
Type: O4
- Ready to switch on
- Operation enabled
index1: 1
Menus:
Unit: -
- Parameter menu
Indices: 2
+ Technology
Type: L2 ,B
+ Synchronism
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
index1: 1
Menus:
Unit: -
- Parameter menu
Indices: 2
+ Technology
Type: L2 ,B
+ Synchronism
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
Dec.Plc.: 3
Menus:
Unit: %
- Parameter menu
Indices: 2
+ Technology
Type: I4
+ Synchronism
- Upread/free access
Dec.Plc.: 0
Menus:
Unit: -
- Parameter menu
Indices: 2
+ Technology
Type: O4
+ Synchronism
- Upread/free access
index1: 0,00
Menus:
Min: 0,00
- Parameter menu
Max:
+ Technology
20000000,00
+ Synchronism
Unit: -
- Upread/free access
Indices: 2
Changeable in:
Type: O4
- Ready to switch on
- Operation enabled
Init: 1
Menus:
Unit: -
- Parameter menu
Indices: -
+ Technology
Type: L2 ,K
+ Synchronism
,K
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
175

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents