Parameter
Description
P123*
Function parameter for entering the stator reactance of a
Stator React
connected induction motor. The value to be entered
corresponds to the stator reactance of a winding phase at
123
40% of the rated motor current. The parameter value is
calculated during the automatic calculation of derived
motor data (P115).
P124*
Function parameter for entering the rotor time constant of
Rotor TimeConst
a connected induction motor. The parameter value is
calculated during the automatic calculation of derived
124
motor data (P115).
P127
Parameter is not used.
R(Rot)Corr'nTmp
127
P128*
Function parameter for entering the maximum current
Max Current
(r.m.s. value of the fundamental component). The output
current is limited to the value entered. The limitation of the
128
output current serves to protect the connected motor.
The maximum current that can be input is limited by
converter current parameter P072. Any derating that may
be necessary because of increased pulse frequency is not
taken into account until r129.
In function diagram 370.5
r129
Visualization parameter for displaying the actually
I(max,set)
effective maximum current (r.m.s. value of the
fundamental component). If utilization of the converter or
129
inverter exceeds 100 % (i2t calculation) or if the maximum-
current limit has been reduced, the displayed value
deviates from the value set in P128. The maximum
current can be reduced, for example, by operation at a
pulse frequency (P340, P357) > 3kHz.
In function diagram 370.5
Siemens AG
6SE7087-6QX70 (Edition AL )
SIMOVERT MASTERDRIVES Compendium Motion Control
Data
Read/write
Init: 0,00
Menus:
Min: 0,00
- Parameter menu
Max: 655,00
+ Motor/encoder
Unit: Ohm
+ Motor data
Indices: -
- Drive setting
Type: O2
- Upread/free access
Changeable in:
- Drive setting
Init: 0
Menus:
Min: 0
- Parameter menu
Max: 10000
+ Motor/encoder
Unit: ms
+ Motor data
Indices: -
- Drive setting
Type: O2
- Upread/free access
Changeable in:
- Drive setting
Init: 70,0
Menus:
Min: 12,5
- Parameter menu
Max: 400,0
+ Control/gating unit
Unit: %
+ Current control
Indices: -
- Upread/free access
Type: O2
Changeable in:
- Ready to switch on
Init: 6,3
Menus:
Min: 0,0
- Parameter menu
Max: 2000,0
+ Motor/encoder
Unit: A
+ Motor data
Indices: -
- Drive setting
Type: O2
- Upread/free access
Changeable in:
- Drive setting
- Ready to switch on
Dec.Plc.: 1
Menus:
Unit: A
- Parameter menu
Indices: -
+ Motor/encoder
Type: I2
+ Motor data
- Upread/free access
16