AT command
AT* DANTE
Displays the FOMA
terminal signal reception
level.
n
AT* DGANSM=
Sets the reject/permit mode
setting for the packet
incoming call. This
command is effective for
those incoming packet calls
after the setting command
is input.
[,cid] Sets APN, which permits
n
AT*DGAPL=
incoming packet calls, by
using <cid> parameter
defined by
+CGDCONT
AT* DGARL=n [,cid]
Sets APN, which rejects
incoming packet calls, by
using <cid> parameter
defined by
+CGDCONT
n
AT* DGPIR=
This command validates
the setting for notifying
Caller ID when sending/
receiving packet
communication.
Even in the dial up network
setting, you can also add
186 (notify) or 184 (not
notify) to the access point
number. (p.35)
AT* DRPW
Displays the indicator value
of the receiving power of
the FOMA terminal.
AT+CAOC
Inquires for the current
charge.
AT+CBC
Displays the battery status
of the FOMA terminal.
Outline
0: FOMA terminal signal reception level is displayed
as out of area.
1: FOMA terminal signal reception level is 0 or 1
bar.
2: FOMA terminal signal reception level is 2 bars.
3: FOMA terminal signal reception level is 3 bars.
n
= 0 : Disables the incoming call reject (AT*
n
= 1 : Enables the incoming call reject
n
= 2 : Enables the incoming call permit
AT * DGANSM?
: Displays the current setting.
n
= 0 : Adds the APN defined by <cid> to
n
= 1 : Deletes the APN defined by <cid>
If <cid> is omitted, this will apply to all cid.
AT * DGAPL?
: Displays incoming call permission
n
= 0 : Adds the APN defined by <cid> to
n
= 1 : Deletes the APN defined by <cid>
If <cid> is omitted, this will apply to all cid.
AT * DGARL?
: Displays incoming call rejection list.
n
= 0 : Uses APN as it is (initial value).
n
= 1 : Uses APN by adding "184". (Caller ID
n
= 2 : Uses APN by adding "186". (Caller ID
AT * DGPIR?
: Displays the current setting.
Result: +CBC:<bcs>,<bcl>
bcs:
0 : FOMA terminal is powered by the
battery.
1 : FOMA terminal is not powered by the
battery.
2 : FOMA terminal is not connected to the
battery.
3 : FOMA terminal is out of transmission
due to the power-supply error.
bcl:
0 : Battery has run out, or battery is not
connected.
1-100 : Battery remained
Parameter/description
DGARL)/permit setting (AT*DGAPL)
(initial value).
setting.
setting.
incoming call permission list.
from incoming call permission list.
list.
incoming call rejection list.
from incoming call rejection list.
is always not sent.)
is always sent.)
47
Command execution example
AT* DANTE
* DANTE:3
OK
AT* DANTE = ?
* DANTE:(0-3)
OK
AT* DGANSM=0
OK
AT* DGANSM?
* DGANSM:0
OK
AT* DGAPL =0,1
OK
AT* DGAPL?
* DGAPL:1
OK
AT* DGAPL =1
OK
AT* DGAPL?
OK
AT* DGARL =0,1
OK
AT* DGARL?
* DGARL:1
OK
AT* DGARL =1
OK
AT* DGARL?
OK
AT* DGPIR =0
OK
AT* DGPIR?
* DGPIR:0
OK
AT* DRPW
* DRPW:0
OK
AT* DRPW=?
* DRPW:(0-75)
OK
AT+CAOC
+CAOC:"000014"
OK
AT+CBC
+CBC:0,70
OK
AT+CBC?
ERROR
AT+CBC=?
+CBC:(0-3),(0-100)