Programming Fundamentals
Programming Command Compatibility Across Model Numbers and Across Modes
Programming Command Compatibility
Across Model Numbers and Across Modes
Across PSA Modes: Command Subsystem Similarities
When you select different modes you get different sets of available
programming commands. That is, only the commands that are
appropriate for the current mode are available. Also, some commands
have the same syntax in different modes but have different ranges or
settings that are only appropriate to the current mode.
The following table shows which command subsystems are the same
across different modes. If there is no "X" by a particular subsystem,
then the set of available commands is different in those modes.
Command ranges or defaults may also be different. Refer to the
programming command descriptions in the documentation for each
mode for details.
Command Subsystem
IEEE common commands
ABORt
CALCulate
CALibration
CONFigure
COUPle
DISPlay
FETCh
FORMat
HCOPy
INITiate
INPut
304
Same command set is
available:
SA mode compared with the
application modes: W-CDMA,
cdmaOne, cdma2000,
1xEV-DO, Basic, GSM, EDGE,
NADC, or PDC
X
X
X
not available in these application
modes
X
not available in these application
modes
Same command set is
available:
SA mode compared with the
application mode: Phase
Noise
X
X
X
not available in this application
modes
X
X
X