Span Zoom; Full Span; Zero Span - Agilent Technologies PSA Series User And Programming Manual

Spectrum analyzers
Hide thumbs Also See for PSA Series:
Table of Contents

Advertisement

Instrument Functions: P - Z
SPAN / X Scale
Remote Command:
[:SENSe]:FREQuency:SPAN <freq>
[:SENSe]:FREQuency:SPAN?
Example:
FREQ:SPAN 2 GHZ

4.7.2 Span Zoom

Turns on signal tracking and activates the span function. Entering a new span value will
then change the span while keeping the marker used for signal tracking centered on the
screen. Pressing
Span Zoom
See
"Signal Track" on page 149
Key Path:
SPAN X Scale
State Saved:
Saved in Instrument State
Remote Command:
No equivalent SCPI command.

4.7.3 Full Span

Changes the displayed frequency span to show the full frequency range of the analyzer.
When using external mixing, it changes the displayed frequency span to the frequency
range specified for the selected external mixing band.
Key Path:
SPAN X Scale
Remote Command:
[:SENSe]:FREQuency:SPAN:FULL
Example:
FREQ:SPAN:FULL

4.7.4 Zero Span

Changes the displayed frequency span to zero Hertz. The horizontal axis changes to time
rather than frequency. The input signal that is at the current center frequency is the
displayed amplitude. This is a special operation mode that changes several measurement
functions/couplings. The instrument behavior is similar to an oscilloscope with a frequency
selective detector installed in front of the oscilloscope. See Application Note 150 for more
information on how to use this mode.
Key Path:
SPAN X Scale
228
is the same as pressing:
.
,
(On), and
Frequency
Signal Track
.
Span
Chapter 4

Advertisement

Table of Contents
loading

This manual is also suitable for:

E4440aE4443aE4445aE4448aE4446a

Table of Contents