Agilent Technologies PSA Series User And Programming Manual page 238

Spectrum analyzers
Hide thumbs Also See for PSA Series:
Table of Contents

Advertisement

Instrument Functions: P - Z
SWEEP
4.8.5.5 Gate Source
Lets you select the input to which the gate signal will be applied.
Key Path:
,
Sweep
Save
State Saved:
Factory Preset: Front (external 1 trigger input)
Remote Command:
[:SENSe]:SWEep:EGATe:SOURce EXTernal[1]|EXTernal2|RFBurst
where Ext1 selects the Front input and Ext2 selects the Rear input.
[:SENSe]:SWEep:EGATe:SOURce?
Example:
SWE:EGAT:SOUR EXT2
4.8.5.5.1 Ext Front (Ext Trig In)
Selects the front panel external trigger input connector as the gate source and sets the
voltage level at which the gate will trigger. Changes made to the trigger level setting with
this key will also change the setting in the
Be careful about selecting trigger level values too far away from the trigger
NOTE
signal's midpoint. If the signal has ringing, it can cause multiple triggers.
Key Path:
,
Sweep
State Saved:
Saved in instrument state
Factory Preset: 1.5 V
− 5 to +5 V
Range:
Remote Command:
See
"Gate Source" on page 238
[:SENSe]:SWEep:EGATe:EXTernal[1]:LEVel <voltage>
[:SENSe]:SWEep:EGATe:EXTernal[1]:LEVel?
Example:
SWE:EGAT:SOUR EXT1
SWE:EGAT:EXT1:LEV 2.5
238
Gate Setup
Trig
,
Gate Setup
Gate Source
menu.