Delta Electronics ASDA-B2 series User Manual page 301

Delta standart ac servo drive of general-purpose applications
Table of Contents

Advertisement

Chapter 10 Specifications
Model: ASD-B2 Series
Voltage Range
Analog Input
Command
Resistance
Time Constant
Command Source
Smoothing Strategy
Speed Limit Operation
Analog Monitor Output
Digital
Inputs/Outputs
Outputs
Protective Functions
Communication Interface
Installation Site
Altitude
Atmospheric pressure
Operating Temperature
Storage Temperature
Humidity
Vibration
IP Rating
Power System
Standards/Requirement
10-2
info@varitel.com - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.
VARITEL INGENIERIA ELECTRONICA S.A.
100W
200W
01
02
Input
Monitor signal can set by parameters (Output voltage range: ±8V)
Servo On, Reset, Gain switching, Pulse clear, Zero speed CLAMP,
Command input reverse control, Speed/Torque limit enabled, Speed
command selection, Position / Speed mode switching, Speed / Torque
Inputs
mode switching, Torque / Position mode switching, Emergency stop,
Forward / Reverse inhibit limit, Forward / Reverse operation torque limit,
Forward / Reverse JOG input, Electronic gear ratio (Numerator) selection
and Pulse inhibit input
Encoder signal output (A, B, Z Line Driver / Z Open collector)
Servo ready, Servo On, At Zero speed, At Speed reached, At Positioning
completed, At Torques limit, Servo alarm (Servo fault) activated,
Electromagnetic brake control, Output overload warning, Servo warning
activated
Overcurrent, Overvoltage, Undervoltage, Motor overheated, Overload,
Overspeed, Excessive deviation, Regeneration error, Abnormal pulse
control command, Encoder error, Adjustment error, Emergency stop
activated, Reverse/ Forward limit switch error, IGBT temperature error,
Serial communication error, Input power phase loss, Serial
communication time out, terminals with short circuit protection (U, V ,W ,
CN1, CN2, CN3 terminals)
Indoor location (free from direct sunlight), no corrosive liquid and gas (far
away from oil mist, flammable gas, dust)
o
o
0
C to 55
C (32°F to 131°F) (If operating temperature is above specified
9.80665m/s
400W
750W
1kW
04
07
10
0 ~ ±10 V
DC
10K
2.2 us
External analog signal / Internal parameters
Low-pass filter
Parameter Setting or via Analog input
RS-232/RS-485
Altitude 1000m or lower above sea level
86kPa to 106kPa
range, forced cooling will be required)
-20
~ 65
0 to 90% (non-condensing)
2
(1G) less than 20Hz, 5.88m/ s
IP20
TN System
IEC/EN 61800-5-1, UL 508C
ASDA-B2
1.5kW
2kW
3kW
15
20
2
(0.6G) 20 to 50Hz
*4
Revision September 2013
30