5.4 Speed Trial Run without Load

Before speed trial run, fix and secure the motor as possible to avoid the danger
from the reacting force when motor speed changes.
STEP 1:
Set the value of parameter P1-01 to 02 and it is speed (S) control mode. After selecting
the operation mode as speed (S) control mode, please restart the drive as P1-01 is
effective only after the servo drive is restarted (after switching power off and on).
STEP 2:
In speed control mode, the necessary Digital Inputs are listed as follows:
Parameter Setting
Digital Input
Value
DI1
P2-10=101
DI2
P2-11=109
DI3
P2-12=114
DI4
P2-13=115
DI5
P2-14=102
DI6
P2-15=0
DI7
P2-16=0
DI8
P2-17=0
DI9
P2-36=0
By default, DI6 is the function of reverse inhibit limit, DI7 is the function of forward inhibit
limit and DI6 is the function of emergency stop (DI8), if the users do not set the setting
value of parameters P2-15 to P2-17 and P2-36 to 0 (Disabled), the faults (ALE13, 14 and
15) will occur (For the information of fault messages, please refer to Chapter 10).
Therefore, if the users do not need to use these three digit inputs, please set the setting
value of parameters P2-15 to P2-17 and P2-36 to 0 (Disabled) in advance.
All the digital inputs of Delta ASDA-B2 series are user-defined, and the users can set the
DI signals freely. Ensure to refer to the definitions of DI signals before defining them (For
the description of DI signals, please refer to Table 7.A in Chapter 7). If any alarm code
displays after the setting is completed, the users can restart the drive or set DI5 to be
activated to clear the fault. Please refer to section 5.2.
Revision September 2013
info@varitel.com - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.
VARITEL INGENIERIA ELECTRONICA S.A.
Sign
SON
TRQLM
SPD0
SPD1
ARST
Disabled
Disabled
Disabled
Disabled
Chapter 5 Trial Run and Tuning Procedure
Function Description
Servo On
Torque limit enabled
Speed command selection
Speed command selection
Reset
This DI function is disabled
This DI function is disabled
This DI function is disabled
This DI function is disabled
CN1 PIN No.
DI1-=9
DI2-=10
DI3-=34
DI4-=8
DI5-=33
-
-
-
-