P0-16
Reserved (Do Not Use)
P0-17
CM1A Status Monitor Selection 1
Operation
Interface:
Default: 0
Control
Mode:
Unit: -
Range: 0 ~ 18
Data Size: 16-bit
Display
Format:
Settings:
This parameter is used to determine the drive status found in P0-02. The selected
drive status will be displayed by P0-09.
For example:
Set P0-17 to 7, then all consequent reads of P0-09 will return the motor rotation speed
in r/min.
P0-18
CM2A Status Monitor Selection 2
Operation
Interface:
Default: 0
Control
Mode:
Unit: -
Range: 0 ~ 18
Data Size: 16-bit
Display
Format:
Settings:
This parameter is used to determine the drive status found in P0-02.
P0-19
CM3A Status Monitor Selection 3
Operation
Interface:
Default: 0
Control
Mode:
Unit: -
Range: 0 ~ 18
Data Size: 16-bit
Display
Format:
Revision September 2013
info@varitel.com - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.
VARITEL INGENIERIA ELECTRONICA S.A.
Keypad/Software
-
Decimal
Keypad/Software
-
Decimal
Keypad/Software
-
Decimal
Chapter 7 Servo Parameters
Address: 0020H
Communication
Communication
Communication
0021H
Address: 0022H
0023H
Related Section: N/A
Address: 0024H
0025H
Related Section: N/A
Address: 0026H
0027H
Related Section: N/A